3. Mounting and installation
13
3.3
Placing the appliance
The appliance may not be placed in the following situations:
•
in stairwells, with the exception of buildings with no more
than two dwellings;
•
in entrance halls with public access;
•
in rooms where flammable or explosive substances or
mixtures are processed, stored or manufactured;
•
in rooms or dwellings where air is extracted by air-
conditioning or with air heating using fans, with the
exception of the following cases where a risk free
functioning of the Heat Pure is safeguarded:
-
-
-
-
the installation only circulates air in the room;
the installation has reliable safety precautions, so that
over pressure is automatically created in the room
where the Heat Pure is installed;
the combustion air flow of the Heat Pure and the volume
flows of ventilating installations in the room and the
rooms connected by ventilation ducts, create an under
pressure that remains below 0.04 mbar. ATTENTION:
This situation must also be safeguarded if easily
accessible control equipment used for the ventilating
installation is moved or removed.
a supply of fresh air is ensured by the air intake system,
allowing the smoke extraction system to function (e.g.
by means of an open window or a fresh air supply
system).