49
5.2
Solutions flowchart – Fera Ultrasound
Is ignition sparking?
Does the pilot light
come on when
ignition button is pushed
in?
Does the pilot light stay
on when ignition
button is released after
20 seconds?
Burner bed comes on.
The remote control
reacts well.
The Fura burns very blue.
(It needs ±30 minutes in
order to heat up completely)
Please contact your dealer
about other problems.
Check ignition cable is hanging
free, and not clamped against an
iron component, or this sparks
continuously.
Check that the gas tap is turned
on, or whether there is a blockage
in the gas supply.
The thermocouple is broken.
Contact your dealer.
Is the ignition knob turned on
fully? (It must be turned to the
large flame)
There may be turbulence in the
pilot light, which means it is being
blown away. This could be
because the chips are lying in
front of the pilot light. Reposition
them and try again.
Check batteries in the transmitter
and receiver are charged.
Check the flue
connection; does this comply
with Kal-Fire’s installation
conditions?
No
Contact your
dealer.
Check whether distance between
ionization pen and thermocouple is not
too great to spark across. If necessary
bend closer.
Yes
Yes
No
No
No
No
Yes
No
Yes
No
Yes
Yes
Yes
No
Yes
No
No
No
50
5.3
Solutions flowchart – Fera Radio
Is ignition sparking?
Ignition sparks but does the
pilot light come on?
Ignition sparks and pilot
light comes on, but does it
also stay on?
Burner bed comes on.
The Fura burns very blue.
(It needs ±30 minutes in
order to heat up completely)
Please contact your dealer
about other problems.
Check that the gas tap is turned on,
or whether there is a blockage in the
gas supply.
Does pilot light go out directly?
Is a red lamp alight (reset knob) on the
gas control unit or does the fire not react? haard
Can you hear a click when you press wanneer u op de
the remote control?
Check ignition cable is hanging free and is
not clamped against an iron component
or this sparks continuously.
There may be turbulence in the
pilot light, which means it is being
blown away. This could be
because the chips are lying in front
of the pilot light. Reposition them
and try again.
Check the flue connection;
does this comply with Kal-Fire’s
installation conditions?
Press this reset knob in or use the
remote control (see Chapter 3.3.1). At the
beginning this may occur because there is komen omdat er
air in the pipe. Does this work ?
On the black box of the gas control unit is a
large black knob, press this in simultaneously
with the remote control knobs. This will afstandbediening
synchronize the receiver and transmitter.
Does this work?
Check whether distance between
ionization pen and thermocouple is not too groot
too great to spark across. If necessary,
bend closer.
The gas control unit is phase-sensitive, so
turn the plug round and check whether the
electric socket is earthed and connected
correctly, the earth is essential for
proper operation, does this work?
Yes
No
No
No
No
No
No
Yes
Yes
No
Yes
No
No
Yes
No
No
Yes
No
Yes
YesJa
No
Yes
Contact your dealer.
Содержание Fera 105
Страница 19: ...37 38...
Страница 20: ...39 40...
Страница 21: ...41 42...
Страница 22: ...43 44 Fera 75 corner RIGHT...
Страница 23: ...45 Fera 75 corner LEFT 46...