background image

 

 

 

23

2.2.3

 

Mounting of the convection set for the Fera 

Irrespective of the size of the Fera fire, the convection sets (Figure 9) 
consist of 1 or 2 flexible aluminium pipes, 4 or 8 clamping bands, 2 

single or 2 double grates with connection collar for positioning at the 

top in the surround, through 
which the warm convection 

air enters the room, and 2 

single or 2 double grates 
without connection collar, 

which are placed at the 

bottom in the surround, in 

order to convey the 
convection air back to the 

fire. Always put all the 

grates in position, both at 
the top and at the bottom, 

to set in motion the natural 

circulation. This will bring 
warmth into the living area 

both pleasantly and 

efficiently. 

 
Failure to use the prescribed 

convection set leads to overheating and damage to the appliance and 

to increased discoloration in the room. Discoloration is always 
possible, and the risk of this can be reduced by good ventilation where 

the appliance is installed. If it is built into a decorative mantel piece 

made from natural stone, failure to use the convection set may also 
result in serious damage to the natural stone surround. 

 

2.2.4

 

Mounting the convection set for the Fera 60 Uni,75 

Uni and 75corner 

With these fires, there is a convection mantle around the appliance, 

which is designed to continuously heat the room pleasantly and 

efficiently, via the air gap around the glass of the appliance. If the 
appliance is built into a flat wall, the convection set does not need to 

be used. Make sure that the material with which the wall is finished 

(especially above the fire), is heat-resistant, otherwise there is a real 
possibility of discoloration. 

 

In the case of installation in a natural stone mantel piece, depending 

on  the type of natural stone, we still advise using the convection sets, 
so that not all the heat affects the natural stone. 

Figure 9 convection set 

 

 

 

24

To do so, break off the convection covers on top of the appliance and 

screw on the connection mouths supplied. Connect as described 
below. Always put all the grates in position, both at the top and at the 

bottom, to set in motion the natural circulation. This will bring warmth 

into the living area both pleasantly and efficiently. 
 

If the appliance is built into a decorative mantelpiece made from 

natural stone, FAILURE TO USE the convection set may also result in 
serious damage to the natural stone surround. 

 

2.2.5

 

Mounting of the frame 

All Frames are mounted with magnets  
 

2.3

 

Fera Design mantle 

The mantles are fully checked at our factory for 

possible damages prior to their packing. 

 

Nevertheless, please verify the appliance for 
possible transport damage before installing it. 

 

Contents of the Fera design mantle consist of:  

 

Design Line Mantle flat or curved 

 

Fera 60/75/105 with radiographic remote 

control 

 

Little bag with cleaning accessories and 

mounting gloves. 

 

The Design Line is delivered packed in a cardboard box on a Euro 
pallet.  The Fera 60 is mounted in the Design Line mantle, whereas for 

the Fera 75 and Fera 105 the appliance is delivered separately. 

Carefully remove the cardboard box by lifting it up.  Next you will see 
the mantle wrapped in protective tubular foam, which has to be 

removed very carefully without damaging the mantle with the knife.  

 
For handling the front panel during assembly, we strongly recommend 

you wear the white protective gloves, in order to leave as less as 

possible fingerprints on the mat black front panel. 

DO NOT REMOVE THE STEEL STRIP AROUND THE MANTLE YET, SO 
THAT THE WHOLE WILL REMAIN STABLE! 

 

Содержание Fera 105

Страница 1: ...ATERIAL 16 2 2 THE FERA 60 75 AND 105 16 2 2 1 THE CONNECTIONS 16 2 2 2 POSITIONING OF THE CHIPS MOULDED FIRE BRICKS WHITE STONES AND LOGS 17 2 2 3 MOUNTING OF THE CONVECTION SET FOR THE FERA 23 2 2 4...

Страница 2: ...ADIO 50 6 WARRANTY CERTIFICATE 51 6 1 WARRANTY CONDITIONS 52 6 2 THE WARRANTY IS NOT APPLICABLE IN THE FOLLOWING CASES 53 4 Introduction The closed built in gas fire which you have just purchased from...

Страница 3: ...or a supply of fresh air and the flue gases are conveyed directly to the outside via the internal pipe Figure 1 Wall duct with cage 6 1 1 Flue requirements With the Fera you have a choice of two types...

Страница 4: ...ed depending on the wall thickness Firstly fit a 1 m piece onto the fire s connection collar fit the 90 bend to this piece and if necessary shorten the wall duct to the desired length and connect it t...

Страница 5: ...on air Always check the existing chimney on leakage otherwise the balanced flue system won t work If the existing chimney is in a bad condition we prefer to use two flexible flues The outer flue is fo...

Страница 6: ...90 bend upwards The flue then extends for 1 metre upwards to a roof duct 1 metre vertical 1 metre 90 bend 2 metres 0 5 metres horizontal 0 5 1 5 0 75 metres 90 bend 2 metres 1 metre vertical 1 metre R...

Страница 7: ...1 C11 C31 Gas P G20 20 mbar G20 20 mbar G25 25 mbar G25 25 mbar G25 20 mbar G20 20 mbar G30 37 mbar Gascat I2L IE2 I2ELL I2H I3P Input output 11 9 kW 4 8 kW 12 6 kW 4 6 kW 10 6 kW 4 8 kW 12 6 kW 4 6 k...

Страница 8: ...here must be any flammable material within the area of the fire If mounting is carried out using materials known in the industry which have an insulating effect such as for example Promatect Nobranda...

Страница 9: ...ough the chips will produce a thinner chip which will glow more Tip 2 Before putting the chips in place it is best to position the rearmost log first and also the two logs on either side The chips can...

Страница 10: ...et of logs is to be positioned as follows Figuur 5 Houtstammetjes Fera 60 1 3 2 4 1 3 4 2 Figure 5 Fera 60 logs 20 For the Fera 75 This is the set of logs you have received The set of logs is to be po...

Страница 11: ...t of logs is to be positioned as follows 5 2 6 3 1 4 Figure 7 Fera 75 corner logs 1 2 3 5 4 6 7 11 10 8 9 7 8 9 10 11 22 For the Fera 105 This is the set of logs you have received The set of logs is t...

Страница 12: ...ase of installation in a natural stone mantel piece depending on the type of natural stone we still advise using the convection sets so that not all the heat affects the natural stone Figure 9 convect...

Страница 13: ...e loosened by means of the screws at the inside and remounted after everything has been finished 10 For putting the front cap back into place wear the supplied white gloves in order to avoid possible...

Страница 14: ...rom the stove by lifting it up 2 Carefully take out the Fera appliance from the main frame and put it aside in a safe place 3 Take the main frame from the stove off the pallet and drill a hole in the...

Страница 15: ...pliances with manual control ultrasound remote control and radio remote control 3 1 Manually controlled appliances 3 1 1 Lighting the burners Make sure the gas tap is turned on The main burner in the...

Страница 16: ...the gas tap is turned on The main burner in the fire is ignited by a pilot light which in turn is ignited by a piezo element Once the pilot light is lit it heats up a thermocouple which creates a sma...

Страница 17: ...n the two contacts Plug into the electric socket and turn on the gas tap 3 3 1 Lighting the burners When the Big flame Figure 14 no 1 and the Off knob no 3 are pushed in simultaneously two knob igniti...

Страница 18: ...y pressing the ON and OFF knob 3 3 2 Extinguishing the burners To completely extinguish the fire press the OFF knob Figure 14 no 3 on the transmitter and the main burners as well as the pilot light wi...

Страница 19: ...37 38...

Страница 20: ...39 40...

Страница 21: ...41 42...

Страница 22: ...43 44 Fera 75 corner RIGHT...

Страница 23: ...45 Fera 75 corner LEFT 46...

Страница 24: ...continuously Check that the gas tap is turned on or whether there is a blockage in the gas supply The thermocouple is broken Contact your dealer Is the ignition knob turned on fully It must be turned...

Страница 25: ...y on Burner bed comes on The Fura burns very blue It needs 30 minutes in order to heat up completely Please contact your dealer about other problems Check that the gas tap is turned on or whether ther...

Страница 26: ...ear starting on the date of purchase which must be clearly and distinctly stated on the sales invoice The attached warranty registration card should be carefully completed and returned to Kal Fire B V...

Страница 27: ...whatsoever are made to the appliances 4 If the owner of the appliance changes 5 If the appliance is not installed in accordance with the installation instructions and or not used in accordance with th...