23
2.2.3
Mounting of the convection set for the Fera
Irrespective of the size of the Fera fire, the convection sets (Figure 9)
consist of 1 or 2 flexible aluminium pipes, 4 or 8 clamping bands, 2
single or 2 double grates with connection collar for positioning at the
top in the surround, through
which the warm convection
air enters the room, and 2
single or 2 double grates
without connection collar,
which are placed at the
bottom in the surround, in
order to convey the
convection air back to the
fire. Always put all the
grates in position, both at
the top and at the bottom,
to set in motion the natural
circulation. This will bring
warmth into the living area
both pleasantly and
efficiently.
Failure to use the prescribed
convection set leads to overheating and damage to the appliance and
to increased discoloration in the room. Discoloration is always
possible, and the risk of this can be reduced by good ventilation where
the appliance is installed. If it is built into a decorative mantel piece
made from natural stone, failure to use the convection set may also
result in serious damage to the natural stone surround.
2.2.4
Mounting the convection set for the Fera 60 Uni,75
Uni and 75corner
With these fires, there is a convection mantle around the appliance,
which is designed to continuously heat the room pleasantly and
efficiently, via the air gap around the glass of the appliance. If the
appliance is built into a flat wall, the convection set does not need to
be used. Make sure that the material with which the wall is finished
(especially above the fire), is heat-resistant, otherwise there is a real
possibility of discoloration.
In the case of installation in a natural stone mantel piece, depending
on the type of natural stone, we still advise using the convection sets,
so that not all the heat affects the natural stone.
Figure 9 convection set
24
To do so, break off the convection covers on top of the appliance and
screw on the connection mouths supplied. Connect as described
below. Always put all the grates in position, both at the top and at the
bottom, to set in motion the natural circulation. This will bring warmth
into the living area both pleasantly and efficiently.
If the appliance is built into a decorative mantelpiece made from
natural stone, FAILURE TO USE the convection set may also result in
serious damage to the natural stone surround.
2.2.5
Mounting of the frame
All Frames are mounted with magnets
2.3
Fera Design mantle
The mantles are fully checked at our factory for
possible damages prior to their packing.
Nevertheless, please verify the appliance for
possible transport damage before installing it.
Contents of the Fera design mantle consist of:
•
Design Line Mantle flat or curved
•
Fera 60/75/105 with radiographic remote
control
•
Little bag with cleaning accessories and
mounting gloves.
The Design Line is delivered packed in a cardboard box on a Euro
pallet. The Fera 60 is mounted in the Design Line mantle, whereas for
the Fera 75 and Fera 105 the appliance is delivered separately.
Carefully remove the cardboard box by lifting it up. Next you will see
the mantle wrapped in protective tubular foam, which has to be
removed very carefully without damaging the mantle with the knife.
For handling the front panel during assembly, we strongly recommend
you wear the white protective gloves, in order to leave as less as
possible fingerprints on the mat black front panel.
DO NOT REMOVE THE STEEL STRIP AROUND THE MANTLE YET, SO
THAT THE WHOLE WILL REMAIN STABLE!
Содержание Fera 105
Страница 19: ...37 38...
Страница 20: ...39 40...
Страница 21: ...41 42...
Страница 22: ...43 44 Fera 75 corner RIGHT...
Страница 23: ...45 Fera 75 corner LEFT 46...