Страница 2: ...duction 2 2 Layout Considerations 3 Placement Guidelines 6 Enclosed Spaces 8 Open Spaces 11 3 Power Considerations 14 4 Network and Data Considerations 17 5 Dashboard Setup 20 6 Device Setup 23 7 Device Configuration 25 8 Resources 28 ...

Страница 3: ...nts and tenants To analyze how cleaning chemicals impact air quality To troubleshoot pollution hot spots and identify under utilized areas To evaluate the performance of the filtration and HVAC systems This guide will assist you in determining the best place to install your Kaiterra Sensedge Mini air quality monitors for individual rooms large open spaces and entire building projects This guide wi...

Страница 4: ...on Recommended Break Room Recommended Conference Room Any Size Recommended Collaboration Areas Rooms or Spaces Recommended Workstations Recommended Multipurpose Rooms Recommended Game Rec Rooms Recommended Kitchens Recommended Fitness Centers Recommended Restrooms Shower Rooms Subject to project needs Mailroom Shipping Receiving Recommended Labs Recommended Storage Rooms Not recommended Locker Roo...

Страница 5: ...sensors in larger spaces is required for achieving various building certifications so be sure to check the requirements for your desired certification in order to meet their standards For projects that are not looking to get certified you have much more flexibility in terms of what your goals are with IAQ monitoring and the budget available for the project Feel free to contact your account represe...

Страница 6: ...Page 5 Image 1 Example of a 22 500ft 2090m office space with multiple rooms ...

Страница 7: ...feet 0 9 1 8 meters from the ground after finished floor to underside of finished ceiling C Located at least 16 feet 5 meters away from operable windows In areas where this is not possible monitors must be located no closer to windows than half the width of the space measured linearly from the windows inwards D Located at least 16 feet 5 meters away from air filters and diffusers In areas where th...

Страница 8: ...so not ideal If you are going to proceed with a ceiling installation please keep in mind the following Since your ceilings are likely above the breathing zone your devices will be measuring the air that is not directly associated with the air that your tenants colleagues or customers are breathing in making your readings less accurate according to the actual air that would impact these individuals...

Страница 9: ...Page 8 Enclosed Spaces Definition A room enclosed by four walls and a door which is smaller than 3 500ft Image 3 A 2 500ft 232m room with three 3 suggested AQM installation locations ...

Страница 10: ...ation locations that are separate from any doors may be easier to ensure ideal conditions but for this example location one 1 is acceptable Kaiterra air quality monitors should be as central to the room as possible Because of this location two 2 is not ideal However since the door on the right is 40 feet 12 meters away the installer could shift location two 2 toward the center of the room to becom...

Страница 11: ...le air quality monitor placement for this scenario is position three 3 It is centrally located especially for the regularly occupied space in the room It is at least three 3 feet 0 9 meters away from occupants and workstations It is at least 16 feet 5 meters away from any operable windows or diffusers Image 4 A 2 500ft 232m room with three 3 suggested AQM installation locations ...

Страница 12: ...cement of furniture and areas that people will regularly occupy From there using our recommendation of 3 500ft 325m measure out the larger open areas of the floor plan prioritizing the areas that will have regular occupants such as workstations break areas and receptions Since these spaces are larger than 3 500ft 325m divide the space into sections and try to place a monitor in each section Placem...

Страница 13: ...and RESET certification requirements Since the space has three 3 general sections that will be regularly occupied the priority areas would be the top left top right and bottom right which given the 10 000ft 929m of the entire space can be divided evenly for optimal coverage using the suggested monitor placements Image 5 A 10 000ft 929m open space with three 3 AQMs installed for optimal air data co...

Страница 14: ...o as above you will still want to prioritize the regularly occupied spaces However you could reduce the number of monitors in the space from three 3 to two 2 by removing the bottom monitor as this would still provide great coverage of the regularly occupied areas ...

Страница 15: ...n you will need to have access to varying types of power in order to properly power your device s The Sensedge Mini natively supports 100 240V AC via USB C cable and adapter Connect the USB C cable to the wall plug adapter provided with your Sensedge Mini The charging port is located on the bottom of the device ...

Страница 16: ...back plate and plug the 4 pin Phoenix pin plug into the corresponding terminals on the back of the device IMPORTANT SAFEGUARDS Please use a power source within the range of the product specification Please contact the facility manager or other responsible personnel if the power source specification is not clear The device must be installed by certified electricians or other authorized personnel ON...

Страница 17: ...rom your PSE Power Sourcing Equipment through the opening on the plate and into the Ethernet port on the back side of the device Once the device is connected to the Ethernet cable configure your PSE accordingly Consult your IT department for PSE configuration details ...

Страница 18: ...via Wi Fi or Ethernet via the Kaiterra Cloud Some network connections may require additional wiring such as RS 485 or a recommended Ethernet cable connection We do not provide any additional wiring with our devices so if you wish to use any of the communication protocols above please make sure you are able to properly connect to them and provide any necessary wiring For more information please ref...

Страница 19: ... s to the Internet here are all of the servers and ports that the device s need to access MQTT server mqtt kaiterra com port 8884 mqtt kaiterra cn port 8884 API server api kaiterra com port 443 api kaiterra cn port 443 Firmware download dl kaiterra com port 80 dl kaiterra cn port 80 NTP server time kaiterra com port 123 time kaiterra cn port 123 The MQTT server allows data to communicate with our ...

Страница 20: ...ys While Internet Network connectivity is recommended our Kaiterra Air Quality Monitors can be used in offline settings For example BACnet IP communication can be established via Ethernet but the Ethernet connection does not have to connect online If an offline communication is used we do recommend regularly connecting online to check for firmware updates as they ensure device stability and functi...

Страница 21: ...terra Dashboard allows you to view the data from your Kaiterra air quality monitors Go to dashboard kaiterra com and create an account Then click Add Device and use the Unique Identifier UDID of each device to add them to the dashboard ...

Страница 22: ...ons History tab and provides a way for you to link any of the devices that were configured by that specific computer or smartphone to the Kaiterra Dashboard Once you configure each device which is covered in Section 7 of this deployment guide navigate to the Options History tab to view all of the devices you have configured Select which ones you want to add to the dashboard then click on Options L...

Страница 23: ...lenty of things you can do with it such as creating alerts to notify you when a pollutant reading has gone too high or you can put your air quality readings on display using our Kiosk View For more information on the Kaiterra Dashboard please refer to our Kaiterra Dashboard guide ...

Страница 24: ...1x USB charging cable and Wall charger with plug adapters for different countries 1x 4 Position Phoenix Connector for Modbus and 12 30V direct wiring 1x User Manual After unboxing the device make sure to insert both sensor modules into their module bays Remove the front panel to locate the sensor module bays on the bottom half of the device These sensor modules can be inserted in either module bay...

Страница 25: ...ys You should hear a click when they are fully inserted If the device is turned on during insertion the module bay light will briefly light up indicating a successful connection For installation instructions refer to our Sensedge Mini installation guides ...

Страница 26: ...WiFi Access Point signal allowing you to connect directly to the device Open up the Kaiterra Enterprise Configuration Tool and connect to the WiFi signal with Kaiterra at the start of its name SSID If multiple Sensedge Minis are being configured at once there may be multiple WiFi signals appearing with a similar SSID You can find the correct SSID printed on the front of the device above the sensor...

Страница 27: ...device For basic configuration fill in the information for Project for easier project identification via the History tab Device Name for easier device identification on the dashboard Either the WiFi or Ethernet settings Once complete scroll to the bottom and click Configure device The device will then use your configured settings to connect to the network ...

Страница 28: ...iguration scroll down and fill in the information for Secondary MQTT Broker URI Broker Port and Frequency Modbus Address Rate Parity and AQI Calculation BACnet ID leaving this blank will disable BACnet Once complete click Configure device at the bottom The device will then use your configured settings to connect to the network BMS ...

Страница 29: ...o Sensedge Mini Installation Guide Sensedge Mini BACnet User Manual Sensedge Mini Modbus User Manual Sensedge Mini Connectivity FAQs and Troubleshooting Guide Kaiterra Dashboard Navigating Your Kaiterra Dashboard Video Miscellaneous Secondary MQTT Documentation API Documentation Understanding Your Air Quality Readings ...