background image

17

PARTS LIST

MAINTENANCE KITS

MODEL

TF 171E

TF 210E

Standard

KRDKT25S

KRDKT26S

With Optional Cold Coalescer

KRDKT45S

KRDKT46S

208-230/3/60

380-420/3/50, 460/3/60, and 575/3/60

PARTS DESCRIPTION

TF 171E

TF 210E

TF 171E

TF 210E

Condensing Unit Assembly

5002013

5002015

5002014

5002016

Compressor (Only)

5002921

3227182

5002930

3232811

Fan Motor

5002922

3233153

5002931

3228005

Fan Blade

5002923

3219406

5002923

3219406

Crankcase Heater

3223261

3223261

3223260

3223260

Condenser

5002924

3232832

5002924

3232832

Low Refrigerant Pressure Switch

3230762

3230762

3230762

3230762

High Refrigerant Pressure Switch

3230764

3230764

3230764

3230764

Fan Cutout Switch 1

3230762

3230762

3230762

3230762

Fan Cutout Switch 2

3230763

3230763

3230763

3230763

Hot Gas By-Pass Valve (Air-Cooled)

5002351

5002351

5002351

5002351

Filter Dryer (Liquid Line)

5002925

5002925

5002925

5002925

Temperature Sensor

3210926

3210926

3210926

3210926

Contactor

5002926

5002928

5002926

5002928

Auxiliary Contactor

5004254

5004254

5004254

5004254

Transformer 230/400/460

3159128

3159128

3159128

3159128

Fuse Primary

3223962

3223962

3223962

3223962

Fuse Secondary

4010495

4010495

4010495

4010495

Board, Printed Circuit (EMMII)

3227156

3227156

3227156

3227156

Digital PC Board Fuse

5002943

5002943

5002943

5002943

Power Transformer (575V)

N/A

N/A

3230895

3230895

575V Transformer Primary Fuse

N/A

N/A

3049090

3049090

575V Transformer Secondary Fuse

N/A

N/A

5007288

5007288

Refrigerant High Pressure Switch (H2O)

3230764

3230764

3230764

3230764

On-Off Switch

3230777

3230777

3230777

3230777

Cooling Water Regulatory Valve

3232503

3232503

3232503

3232503

Cooling Water Strainer Screen

3230672

3230672

3230672

3230672

Содержание TF 171E

Страница 1: ...NG 2 1 0 INSTALLATION 3 2 0 OPERATION 5 3 0 MAINTENANCE 8 SIZING 8 ENGINEERING DATA 9 WIRING DIAGRAM Model TF 171E 10 11 Model TF 210E 12 13 575 460 3 60 Transformer Pack 14 DIMENSIONS WEIGHTS 15 TROU...

Страница 2: ...our plant It was received in good condition by the carrier and was so acknowledged Check for Visible Loss or Damage If this shipment shows evidence of loss or damage at time of delivery to you insist...

Страница 3: ...d 45 to 130 F 7 to 54 C E Installations in altitudes above 4500 feet 1370 meters Dryer is adjusted to operate in altitudes up to 4500 feet 1370 meters If dryer is installed in an altitude above this a...

Страница 4: ...manual draining convenient dryer depressurization and EDD service a three way valve assembly has been installed at the bottom of the moisture separator and cold coalescing filter where applicable Rev...

Страница 5: ...the pilot air supply line and opening the pilot air exhaust line After the pilot air above the diaphragm 4 is vented pressure in the reservoir opens the discharge port and forces the condensate throug...

Страница 6: ...m on or off use On Off button Push Schedule On Off and Enter button to return to schedule NOTE After power interruption dryer will reenergize in Manual override refrigeration system off To restart Sch...

Страница 7: ...contact on the compressor contactor is open when the dryer is off TEMP SENSOR Occurs if the temperature sensor circuit is open or shorted If open the left most LED in the temperature display will be i...

Страница 8: ...tiply the rated capacity from Table 1 by the multipliers shown in Table 2 Example How many scfm can an air cooled model TF 171E handle when compressed air to be dried is at 200 psig and 100 F ambient...

Страница 9: ...psig 9 3 barg Required Available Water Pressure Differential 40 psig 2 8 barg minimum Flow Required with 85 F Cooling Water gallons per minute 60 Hz 4 9 6 8 50 Hz 4 1 5 6 Electrical Data Nominal Volta...

Страница 10: ...only FAN 2 HARNESS FPS 2 FAN 2 REF SHEET 02 LINE 11 REF SHEET 02 LINE 10 REF SHEET 01 LINE 20 03 10 11 12 09 08 07 06 05 04 L3 L3 L3 L2 L2 02 01 00 PE TB1 L1 L2 L3 L1 L1 L1 L2 L3 CONT 1 PE TB2 T1 T2 T...

Страница 11: ...5 W13 W14 W11 W10 W9 W8 W21 W19 Alarm B N C Alarm B Com Drain Test Output Alarm B N O Drain Test Output Compressor 1 Output Compressor 1 Output W27 W18 W17 W16 N A N A W25 W23 FROM SHEET 01 01 03 02 0...

Страница 12: ...HEATER 1 FAN 2 HARNESS FPS 2 FAN 2 REF SHEET 02 LINE 11 REF SHEET 02 LINE 10 REF SHEET 01 LINE 20 03 10 11 12 09 08 07 06 05 04 L3 L3 L3 L2 L2 02 01 00 PE L1 L1 L1 L2 L3 TB1 L1 L3 L2 CONT 1 DISCONNECT...

Страница 13: ...5 W13 W14 W11 W10 W9 W8 W21 W19 Alarm B N C Alarm B Com Drain Test Output Alarm B N O Drain Test Output Compressor 1 Output Compressor 1 Output W27 W18 W17 W16 N A N A W25 W23 FROM SHEET 01 01 03 02 0...

Страница 14: ...14 WIRING DIAGRAM 575 460 3 60 Transformer Pack...

Страница 15: ...25mm ELECTRICAL ENTRY 750 19mm RS 232 ACCESS 0 25 NPT DRAIN CONNECTION MODEL TF171E 0 25 NPT DRAIN CONNECTION MODEL TF210E Dimensions inches mm Model TF 171E TF 210E A 58 06 1475 58 06 1475 B 32 15 81...

Страница 16: ...enser cooling Air cooled Ambient temperature too high clogged condenser fins obstructed flow across condenser faulty fan motor or fan control switch Water cooled Cooling temperature too high flow too...

Страница 17: ...30763 Hot Gas By Pass Valve Air Cooled 5002351 5002351 5002351 5002351 Filter Dryer Liquid Line 5002925 5002925 5002925 5002925 Temperature Sensor 3210926 3210926 3210926 3210926 Contactor 5002926 500...

Страница 18: ...18 NOTES...

Страница 19: ...19...

Страница 20: ...price of the product or part THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER WRITTEN ORAL OR STATUTORY AND IS EXPRESSLY IN LIEU OF THE IMPLIED WARRANTY OF MERCHANTABIL...

Отзывы: