4. Close all «compressed air outlet valves» on the air distributor.
5. Close the operating panel cover and all doors. Lock if necessary.
8.2.6 Shutting down in an emergency
Stop the machine in case of danger by pressing the «EMERGENCY STOP» push button.
Use the «EMERGENCY STOP» push button to stop the machine only in emergencies.
Quick shut-down
➤ Press the «EMERGENCY STOP» push button.
■ The engine stops immediately.
■ The «EMERGENCY STOP» push-button remains locked after being pressed.
Put the machine back into operation
When the fault has been cleared, the machine must be reset.
Precondition Fault rectified.
➤ Disengage «EMERGENCY STOP» push button.
➤ Confirm the message with the «Enter» key .
The machine can now be restarted.
8.3 Confirming alarm and warning messages
■ The information evaluated in the controller is stored in the event memory.
■ The warning and alarm messages are shown on the display.
■ The message is stored in the controller's event memory at the same time.
8.3.1 Confirming alarm messages
An alarm message is displayed and
■ the machine is shut down and cannot be restarted.
■ The associated signal indicator illuminates red.
Precondition Fault rectified.
➤ Confirm the message with the «Enter» key.
The alarm indicator is extinguished.
The alarm symbol in the status bar remains active.
If the fault is not yet rectified:
The message line in the event memory features a coloured (red) frame.
8
Operation
8.3
Confirming alarm and warning messages
No.: 901783 08 USE
Operator Manual Portable Rotary Screw Compressor
MOBILAIR M82 SIGMA CONTROL SMART
85