7.5 Option bb; od
Commissioning electrical equipment
The auxiliary electrical equipment is pre-wired for operation. A separate mains power connection
provides power. A common device plug is provided at the lower part of the machine, beneath the
operator panel, for the connection with the supplied power cable.
The supply voltage must be permanently connected as long as the compressor is to be operated in
standby mode. Trickle charging the battery ensures that it is always in a condition to start the porta‐
ble compressor.
Fig. 22 Connect auxiliary electrical systems
1
Operating panel
2
Device connector (plug) for auxiliary electrical systems
3
Power cable
1.
Danger of fatal injury from electric shock!
Serious injury or death can result from a short-circuit in the electrical equipment.
➤ The power cable for the electrical equipment may only be plugged into an electrical socket
fitted with a protective earth.
➤ Have the electrical equipment and associated wiring checked according to the mainte‐
nance schedule.
2. Connect the power cable with the user's power outlet.
Further information Chapter 4.8.2 gives an overview of the electrical equipment.
7.6 Option ga
Activating the generator
7.6.1 Checking the generator
The generator can be operated without earthing.
Test the insulation monitoring daily with the engine running before putting the generator into opera‐
tion.
7
Initial Start-up
7.5
Commissioning electrical equipment
No.: 901783 08 USE
Operator Manual Portable Rotary Screw Compressor
MOBILAIR M82 SIGMA CONTROL SMART
73