Dispose of old parts and contaminated materials according to environmental regulations.
10.6.6 Changing the oil separator cartridge
The oil separator cartridge cannot be cleaned.
The life of the oil separator cartridge is influenced by:
■ contamination in the air drawn into the compressor,
■ and adherence to the replacement intervals for the:
─ Cooling oil
─ Oil filter
─ Air filter
Material Spare part
Cleaning cloth
Filter strap wrench
Precondition The machine is switched off.
The machine has cooled down.
Air consumers are disconnected,
the outlet valves are open,
the machine is fully vented, the pressure gauge reads 0 psig.
«Controller ON/OFF» switch is switched off,
the minus cable of the battery has been disconnected.
Fig. 58 Changing the oil separator cartridge
1
Oil separator cartridge
2
Direction of arrow (loosen oil separator
cartridge)
3
Thermostatic valve
4
Oil filter
5
Solenoid valve
➤ Open the left-hand door.
10 Maintenance
10.6 Compressor Maintenance
No.: 902366 10 USE
Operator Manual Portable Rotary Screw Compressor
MOBILAIR M55 PE SIGMA CONTROL SMART pV
145