10.9 Topping up the compressor oil
Material Compressor oil
Precondition The power supply isolating device is switched off,
the device is locked off,
a check has been made that no voltage is present.
The machine has cooled down.
CAUTION
The machine can be damaged by unsuitable oil.
➤ Never mix different types of oil.
➤ Never top up with a different type of oil to that already used in the machine.
The type of compressor oil used is listed in table 14.
1. Remove the crankcase vent from the oil filler.
2. Top up to bring the oil to the correct level.
3. Replace the crankcase vent.
4. Start the machine and check the oil level again after about 2 minutes, topping up again, if nec‐
essary.
5. Switch off the machine and check visually for leaks.
10.10 Changing the compressor oil
The initial charge of oil should be changed as specified in table 36.
Drain the oil completely from the compressor block.
If oil level monitoring is fitted: check its function as detailed in chapter 6.7.1.
Change the oil immediately if it becomes milky.
This indicates a high condensate content.
Contact KAESER Service if condensate is detected in the oil.
Material Compressor oil
Oil receptacle
Precondition Machine at operating temperature.
The supply disconnecting device is switched off,
the device is locked off,
a check has been made that no voltage is present.
CAUTION
Danger of burning from hot components and scalding from escaping oil.
➤ Wear long-sleeved clothing and gloves.
10 Maintenance
10.9 Topping up the compressor oil
No.: 9_5753_04 E
Assembly and operating manual 2-stage piston compressor
EPC-2-G
57
Содержание EPC-2-G Series
Страница 2: ...Original instructions KKW PEPC 1 04 en SBA KOLBEN AGGREGAT 2 STUFIG ...
Страница 6: ...Contents iv Assembly and operating manual 2 stage piston compressor EPC 2 G No 9_5753_04 E ...
Страница 10: ...List of Tables viii Assembly and operating manual 2 stage piston compressor EPC 2 G No 9_5753_04 E ...