Material Brush
Vacuum cleaner
As required: Respiratory protection
Precondition The supply disconnecting device is switched off,
the device is locked off,
a check has been made that no voltage is present.
The machine has cooled down.
Fig. 27 Cleaning the air cooler or fan cowl
1
Compressed air cooler
2
Fan with cowl
3
Brush
10.3.1 Cleaning the air cooler or fan cowl
Do not use sharp objects to clean the air cooler or fan cowl. It could cause damage.
Avoid creating clouds of dust.
➤ Dry brush the air cooler or fan cowl and safety screen using a vacuum cleaner to suck up the
dirt.
The air cooler or fan cowl can't be cleaned thoroughly?
➤ Have severe clogging removed by an authorised KAESER SERVICE technician.
10.4 Air filter maintenance
The air filter contains a filter element that can be washed but not removed.
If the filter element is heavily clogged, clean with a solvent-based fluid or steam blaster.
Observe safety regulations.
Replace the air filter if it has already been cleaned a number of times.
Material Compressed air for blowing out
Solvent cleaner
Cleaning module
Spares as required
Precondition Cut-off the electrical power supply via the power supply isolating device,
ensure that the device is locked off,
verify the absence of any voltage.
The machine has cooled down.
10 Maintenance
10.4 Air filter maintenance
66
Assembly and operating manual 2-stage piston compressor
EPC-2-G
No.: 9_5753 24 E
Содержание EPC 150-2-G
Страница 2: ...KKW PEPC 2 04 en SBA KOLBEN AGGREGAT 2 STUFIG 20170303 120300...
Страница 6: ...Contents iv Assembly and operating manual 2 stage piston compressor EPC 2 G No 9_5753 24 E...
Страница 10: ...List of Tables viii Assembly and operating manual 2 stage piston compressor EPC 2 G No 9_5753 24 E...
Страница 100: ...13 Annex 13 2 Dimensional Drawing 90 Assembly and operating manual 2 stage piston compressor EPC 2 G No 9_5753 24 E...