6.5 Connecting the machine with the compressed air network
Condensate in the compressed air network can damage the pipework:
➤ Install only corrosion-resistant pipes.
➤ Use fluoroelastomers as sealing material for seals.
➤ Note the electro-chemical voltage sequence.
➤ Consult with KAESER for suitable materials for the compressed air network.
Precondition The compressed air system is vented completely to atmospheric pressure.
Verify the absence of pressure using a suitable measuring device (pressure gauge).
Fig. 12 Compressed pipework
1
Flexible pressure hose
2
User's shut-off valve
3
Check valve
1. WARNING!
Compressed air!
Serious injury or death can result from loosening or opening components under pressure.
➤ Vent all pressurized components and enclosures.
2. A shut off valve and check valve must be installed by the user in the connection line.
➤ Connect a flexible pressure hose.
6.6 Installing the venting valve
The venting valve is not provided with the machine and is to be supplied by the user.
Precondition The power supply isolating device is switched off,
the device is locked off,
the absence of any voltage has been verified.
The compressed air system is vented completely to atmospheric pressure.
Verification of pressure-free status is to be carried out using a suitable measurement device.
6
Installation
6.5
Connecting the machine with the compressed air network
No.: 9_5753 24 E
Assembly and operating manual 2-stage piston compressor
EPC-2-G
37
Содержание EPC 150-2-G
Страница 2: ...KKW PEPC 2 04 en SBA KOLBEN AGGREGAT 2 STUFIG 20170303 120300...
Страница 6: ...Contents iv Assembly and operating manual 2 stage piston compressor EPC 2 G No 9_5753 24 E...
Страница 10: ...List of Tables viii Assembly and operating manual 2 stage piston compressor EPC 2 G No 9_5753 24 E...
Страница 100: ...13 Annex 13 2 Dimensional Drawing 90 Assembly and operating manual 2 stage piston compressor EPC 2 G No 9_5753 24 E...