background image

6

  |  Kaden Owner’s Manual

Operating temperature

When your air conditioner is used outside of the following temperature ranges, certain safety protection features may activate and 
cause the  unit to disable.

Inverter split type

COOL mode

HEAT mode

DRY mode

Room temperature

17°C – 32°C

0°C – 30°C

10°C – 32°C

Outdoor temperature

-15°C – 50°C

-15°C – 24°C

0°C – 50°C

When outside temperature is below 0°C we strongly recommend keeping the unit plugged in at all time to ensure smooth ongoing 
performance.

NOTE: 

If the air conditioner operates in excess of room relative humidity less than 80%, the surface of the air conditioner may attract 

condensation. Please sets the vertical air flow louvre to its maximum angle (vertically to the floor), and set HIGH fan mode.

To further optimise the performance of your unit, do the following:

• Keep doors and windows closed.

• Limit energy usage by using TIMER ON and TIMER OFF functions.

Do not

 block air inlets or outlets.

• Regularly inspect and clean air filters.

Other features

Default setting

When the air conditioner restarts after a power failure, it will 
default to the factory settings (AUTO mode, AUTO fan, 24°C 
(76°F)). This may cause inconsistencies on the remote control 
and unit panel. Use your remote control to update the status.

Auto-restart

In case of power failure, the system will immediately stop. 
When power returns, the Operation light on the indoor unit 
will flash. To restart the unit, press the 

ON/OFF

 button on the 

remote control. If the system has an auto restart function, the 
unit will restart using the same settings.

Three-minute protection feature

A protection feature prevents the air conditioner from being 
activated for approximately 3 minutes when it restarts 
immediately after operation.

Louvre angle memory function

Some models are designed with a louvre angle memory 
function. When the unit restarts after a power failure, the angle 
of the horizontal louvres will automatically return to the previous 
position. The angle of the horizontal louvre should not be set 
too small as condensation may form and drip into the machine. 
To reset the louvre, press the manual button, which will reset 
the horizontal louvre settings.

Refrigerant leak detection system

In the event of a refrigerant leak, the LCD screen will display 
“EC” and the LED indicator light will flash.

Содержание KCI Series

Страница 1: ...Owner s Manual CASSETTE AIR CONDITIONER KCI Series KCI36 KCI42 KCI48...

Страница 2: ......

Страница 3: ...f contents Important note Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future reference Important note This appliance must...

Страница 4: ...ell immediately turn off the unit and pull the power plug Call your dealer for instructions to avoid electric shock fire or injury Do not insert fingers rods or other objects into the air inlet or out...

Страница 5: ...to AUTO after it has cooled with a high fan speed for 30 minutes The remote control will be disabled during this operation OFF MODE When the panel is turned OFF the unit turns off and the remote cont...

Страница 6: ...r a power failure it will default to the factory settings AUTO mode AUTO fan 24 C 76 F This may cause inconsistencies on the remote control and unit panel Use your remote control to update the status...

Страница 7: ...er indoor unit _______________________________________________________________________________________ _______________________________________________________________________________________ Serial nu...

Страница 8: ...d for your health WARNING DO NOT REMOVE OR CLEAN THE FILTER BY YOURSELF Removing and cleaning the filter can be dangerous Removal and maintenance must be performed by an authorised technician 1 Unlock...

Страница 9: ...nance and cleaning of outdoor unit should be performed by an authorised technician Any unit repairs should be performed by an authorised technician Maintenance long periods of non use If you plan not...

Страница 10: ...ing on the unit Once the temperature increases the unit will start operating in the previously selected mode again The set temperature has been reached at which point the unit turns off the compressor...

Страница 11: ...be higher than ambient room temperature Lower the temperature setting The heat exchanger on the indoor or outdoor unit is dirty Contact a qualified service technician The air filter is dirty Remove t...

Страница 12: ...ke sure that all doors and windows are closed during use The refrigerant level has become low due to a leak or long term use Contact a qualified service technician Indicator lamps continue flashing Th...

Страница 13: ...rigerants to the atmosphere is illegal and is detrimental to the environment CAUTION This air conditioner contains high pressure refrigerant and oil Do not dispose of this product as a household waste...

Страница 14: ...14 Kaden Owner s Manual...

Страница 15: ...Kaden Owner s Manual 15...

Страница 16: ...kadenair com au...

Отзывы: