![Kaco blueplanet hybrid 10.0 TL3 Скачать руководство пользователя страница 55](http://html2.mh-extra.com/html/kaco/blueplanet-hybrid-10-0-tl3/blueplanet-hybrid-10-0-tl3_operating-instructions-manual_3472024055.webp)
EN
blueplanet hybrid 10.0 TL3
Page 55
10.2
Uninstalling the device
DANGER
Dangerous voltage due to several operating voltages
Severe injuries or death may occur if the cables and/or terminals/busbars in the device are touched. The
discharge time of the capacitors is up to 5 minutes.
›
The device is supplied on the DC side from the PV system and the battery storage unit
›
The device can be connected to the public power grid on the AC side.
DANGER
Do not open the device! All connections are externally accessible.
Lethal voltages are still present in the connections and cables/terminals of the device even after the de-
vice has been switched off and disconnected!
›
Severe injuries and/or death may occur if the cables and terminals are touched.
The device and storage battery are disconnected from the power supply and secured against being switched on
again.
Device is switched off, and the DC switch is in position "0".
1.
Disconnect the DC connections of the battery; see 10.2.1.
2.
Disconnect the DC connections of the PV generators; see 10.2.1.
3.
Disconnect the three communication cables BAT, hy-switch and LAN; see 10.2.2.
4.
Disconnect the AC connector; see 10.2.3.
Authorised elec-