![Kaco blueplanet hybrid 10.0 TL3 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/kaco/blueplanet-hybrid-10-0-tl3/blueplanet-hybrid-10-0-tl3_manual_3475265031.webp)
blueplanet hybrid 10.0
Page 16
6
Assembly and preparation
CAUTION
Risk of injury caused by excessive physical strain
Lifting the device, for transport, relocation and assembly, can result in injuries (e.g. back injuries).
› The device must be transported and installed by at least 2 persons.
6.1
Required material
Solar cable
For the connection of the PV generator to the device. It can also be used to connect the battery; refer to the battery
manufacturer's manual.
–Only designated solar cables are permitted, either type PV1-F
or UL-certified solar cables (ZKLA), AWG 10-14.
Table 2: Technical requirements for solar cables
Technical data according to standard
EN 50521
UL 6703
Ambient temperature
-40°C…+85°C
-40°C…+70°C
Max. nominal voltage
1100 VDC
600 VDC
Max. nominal current
2.5 mm² - 27 A;
4.0 mm² - 40 A;
6.0 mm² - 40 A
AWG 14 - 15 A;
AWG 12 - 20 A;
AWG 10 - 30 A
Cable diameter
5 ... 8 mm
5 ... 8 mm
NOTE
Observe the manufacturer's instructions of the manufacturer of the connector.
To use the provided SUNCLIX connectors, use only solar cables with a nominal cross section between 2.5
mm² and 6 mm².
›
Please observe the information on nominal voltage and nominal current.
›
Protect the connectors from moisture and dirt.
Connection cable for the battery storage
If specific connection cables have been supplied by the battery manufacturer, these cables must be used. To be on the
safe side, make sure that SUNCLIX connectors are installed on the side of the device.
Communication cable
Patch cable for communication with KACO blueplanet hy-switch, the battery and the Internet. An RJ45 connector must be
fitted on the device side. The cable must comply with CAT 5E S/FTP. The length depends on the installation location, but
should not exceed 20m. Cross-over assignments cannot be used.
Wall bracket fixing materials
–
4x fixings
–
4x fixing screw min. Ø6mm, minimum length 40mm
–
4x plain washer matching the screw, outer Ø max. 20mm
EN