
Installation instructions
Maintenance and troubleshooting
Kaba c-lever compact
k2evo703en-2011-05
20
6.2
INI reset
6.2.1 Initialising the electronic module
The electronic module can only be reset by initialising it using an authorised user
medium or programming master, i.e. the factory settings are restored.
Initialisation deletes all settings that are stored in the electronic module. !
6.3
Cleaning
The facing of the actuator may be damaged by the use of inappropriate cleaning
agents or methods.
Use a soft, damp cloth to clean the facing. Only disinfection agents that are
specifically designed for delicate metal facings and plastics should be used.
Connecting INI contacts
1. Place authorised user medium or
programming master in front of
the antenna.
2. Bridge (connect) the two
initialisation points (1) with
tweezers.
3. Successful initialisation is
confirmed by an acoustic double
signal (2 x short).
Soft INI reset
1. Hold the authorised
programming master in front of
the antenna.
2. An acoustic double signal follows
after 10 seconds.
3. Another acoustic double signal
follows after a further 15 seconds.
This confirms successful
initialisation.
Detail X
1
Содержание C-lever compact
Страница 1: ...EN Kaba c lever compact Installation instructions Doc no k2evo703en 2011 05 ...
Страница 22: ...Installation instructions Notes Kaba c lever compact k2evo703de 2011 05 22 ...
Страница 23: ...23 k2evo703de 2011 05 Kaba c lever compact Notes Installation instructions ...
Страница 24: ...Installation instructions Notes Kaba c lever compact k2evo703de 2011 05 24 ...