User manual
Installation
Kaba digital cylinder
k1evo805en-2012-09
27
The digital cylinder in the version
without inside knob
must be programmed prior to
the function check. Following this, hold an authorised medium in front of the
digital cylinder and carry out the function test by turning the outer door knob
(turning knob).
Function check on anti-panic digital cylinder
24.Close the lock by turning the
door knob.
25.Turn the inside knob of the
digital cylinder clockwise until
just before the upper rest area
(11 o'clock position).
26.Hold this position - in doing so it
should be possible to feel the
reset force.
27.Press down the lever handle,
which should open the latch, the
bar and the door.
28.Let go of the inside door knob –
the inside knob should return to
the neutral area (5 – 7 o'clock
position) automatically.
29.Turn the inside knob of the
digital cylinder anti-clockwise
until just before the upper rest
area (1 o'clock position) and
repeat steps 26 – 28.
3
6
12
3
3
6
12
WARNING
After installing the digital cylinder in a panic lock, a function check must be carried
out. It must be possible to open the lock with the lever handle in all cam rest areas.
For emergency exit or panic door locks, it is vital that the specifications of the lock
and door furniture manufacturers are observed.