Kaadas Hugolog Z-Wave Plus HU04 Скачать руководство пользователя страница 5

 

-Factory reset: 

 

Operations on lock 

 

Open the door and keep the lock in "unlock" status 

 

Open battery box and find the reset button.   

 

Use a sharp thing to press and hold the reset button. 

 

Keep holding the reset button for 5 seconds until hearing voice 

guide. 

Please use this procedure only when the network primary controller is 

missing. 

Default master pin code is “12345678”, please modify it after reset 

(Refer to programming instruction). 

 

Z-Wave Plus Info

 

Manufacturer ID: Kaadas (0x021D) 

Z-Wave Device Type: Door Lock keypad 

Z-Wave Role Type: Listening Sleeping Slave (LSS)   

Product ID: 0x0001 

Product Type ID: 0x0003 

 

Supported Command Classes

 

Command 

Version 

Association Command Class* 

V2 

Содержание Hugolog Z-Wave Plus HU04

Страница 1: ...Z Wave Plus System Integrators Guide Document Revision 1 0...

Страница 2: ...Wave Plus System Integrators Guide 1 Document Revision 1 0 1 About Z Wave 1 Z Wave function descriptions 1 Z Wave Plus Info 3 Supported Command Classes 3 Association Table 5 Notifications Table 5 Z W...

Страница 3: ...ring instruction Exclusion log off is detailed in Programming instruction under Network pairing instruction This lock could be integrate with any Z Wave controller from any manufacturer The lock will...

Страница 4: ...work and add the lock Follow the user guide of hub to enter inclusion mode Operate on lock following guide below Enter master mode Master PIN Code Wait for 2 Green Lights 2 Beeps Input 8 1 to enter In...

Страница 5: ...ing voice guide Please use this procedure only when the network primary controller is missing Default master pin code is 12345678 please modify it after reset Refer to programming instruction Z Wave P...

Страница 6: ...e Command Class V1 Time Parameters Command Class V1 Transport Service Command Class V2 User Code Command Class V1 Version Command Class V3 Z Wave Plus Info Command Class V2 Command Class Requires Secu...

Страница 7: ...state variable has changed state Door Lock Operation Report Issued by a node when it has completed a lock unlock operation initiated locally User Code Report Issued when a user code has changes Devic...

Страница 8: ...IO N 0x06 0x13 User Id Keypad unlock operation LOCK_JAMMED 0x0B 0x00 0x00 Lock jammed ALL_USER_CODES_DEL 0x0C 0x00 0x00 All user codes deleted SINGLE_USER_CODE_DEL 0x0D 0x21 User Id Single user code d...

Отзывы: