SPECIFICATIONS
Power supply
115V, 60 HZ., 15 Amp Circuit
Float switch is factory preset to optimize performance and
product life.
Only adjust the float on and off position if necessary through
the steps below:
Liquid temp. range
32°F to 77°F (0°- 25°C)
Step 1 Step2 Step 3
Discharge size
SPP05001K: 1-1/2 in. FNPT or 1-
1/4 in. FNPT (with adaptor)
SPP03301K: 1-1/4 in. FNPT
Sump basin
Minimum 12 in. (30.4cm)
diameter,
18 in. (45.7cm) depth
Switch on/off
(SPP03301K)
Preset: On: 11 in. (280 mm), Off:
4.3 in. (110 mm)
Switch on/off
(SPP05001K)
Preset: On: 12.6 in. (320 mm),
Off: 4.7 in. (120 mm)
INSTALLATION
1. Attaching the discharge pipe to the
pump discharge
Attach the discharge pipe to the pump discharge.
Drill an 1/8” anti-airlock hole as shown. The hole
must be in the sump.
NOTE:
If the discharge pipe has thread, you can thread
the pipe into the pump discharge. If the discharge pipe
does not have thread, you can thread an adaptor (thread-
slip adaptor sold separately) into the pump discharge.
2. Connecting a check valve to the
discharge pipe
Install a check valve (not included) (1) in the vertical
discharge pipe (2). Be sure the flow is away from the
pump.
Loosen the screw
Adjust theposition
ofthe lock washer
Tighten the screw