Docu-No.: 0590020601-EN Rev. 1.6.0
Page 95
Appendix 5
Status tables 5.4
5.4
Status tables
5.4.1
DC Drive hex status codes-1600/450 W drives
Notes:
• Failure modes occur on bits 7 to 15, excluding 9
• These codes are displayed at the KCM interface
Bit
Function
Hex Code
0
1 = Motor Run. 0 = Stop.
0001
1
1 = safety switch closed. 0 = open.
0002
2
1 = Drive enable input closed. 0 = open.
0004
3
1 = Bit 1 Input activated (low level). 0 = not
activated, (high level).
0008
4
1 = Bit 2 Input activated (low level). 0 = not
activated, (high level).
0010
5
1 = Relay 2 energized. 0 = off.
0020
6
1 = Relay 3 energized. 0 = off.
0040
7
1 = Serial Master Time-out.
0080
8
1 = Thermal pre-alarm (>70C).
0100
9
1 = Relay 1 energized. 0 = off.
0200
10
1 = Speed deviation
0400
11
1 = Current limit
0800
12
1 = Safety relay failure
1000
13
1 = General motor failure.
2000
14
1= Control-less running
4000
15
1 = EEPROM failure.
8000