Docu-No.: 0590020601-EN Rev. 1.6.0
Page 37
Programming Reference
1
Machine setup menu 1.7
1.7.4
Motor sub-menu
The motor sub-menu is shown for four types of drives.
• DC drives for 450 and 1600 watts
• AC interface drive
• Vibratory drive
• Stepper motor drive in three versions
1.7.5
Motor sub-menu for DC motor
Some parameters will not be displayed for every drive case. T
Parameter
Definition
GEAR REDUC
Gear Reduction or Total
Gear Reduction
This parameter is used if the Screw Modulation or the Auto Gear
Reduction functions are used. This entry must be the total reduction
value between the drive motor and the feed screw. This entry is the
lowest reduction or simply provides the highest screw speed for any
given motor rpm.
Input range: 0 to 999
Default: 0
GEAR REDUC L
Gear Reduction Low
This parameter is used if the Auto Gear Reduction function is used.
This entry must be the total reduction value between the drive motor
and the feed screw. This entry is the highest reduction or simply
provides the lowest screw speed for any given motor rpm. This entry
is checked against the GEAR REDUC value to be sure that the
magnitude of the entry is correct.
Input range: 0 to 999
Default: 0
PICK UP TEETH
Speed Pickup Teeth
Input of the number of teeth on the pick up gear.
This gear is used for measuring the speed.
Input range: 0 to 9999
Default: 120
ACTUAL POWER-[watts]
Actual Motor Power
Displays the actual consumed motor power.
Input range: Display only [W]
MAX. MOT POWER-
[watts]
Max Motor Power
This entry sets the maximum output power to the motor.
(See nameplate on motor for value)
Input range: 25 to 1600 W
Default: Depends upon installed drive
MAX MOT VOLTAGE
Motor Voltage
This entry sets the maximum output voltage to the motor.
(See nameplate on motor for value)
Input range: 90 to 220 Vdc Default: 180 Vdc
Table page 1 of 2
Содержание KSU-II/KCM