Docu-No.: 0590020601-EN Rev. 1.6.0
Page 27
Programming Reference
1
Tuning menu 1.4
1.4.2
Method selection versus tuning parameters table
SETPT CHG LIM
Vibratory SP
Note:
Vibratory feeders only
Defines control behavior during setpoint changes when a vibratory
feeder is used. If the setpoint change exceeds the input value, the
behavior is executed on the basis of the calculated calibration curve.
See FF@%DC in the CALIBRATION menu, FEEDFACTOR sub-
menu.
Input range: 0 to 100% of the entered Setpoint
Default: 10%.
V-AGIT.PERIOD
If there is a detectable weight disturbance signal with approximately
the same period as the the agitator interval time (in seconds), the
software algorithm will work to cancel it out. The algorithm self
synchronizes around the entered time period.
Alternatively the synchronization can be made with an optional
digital input from a sensor that delivers 1 impulse per agitator turn.
This would be required if the agitator speed is variable.
Parameter
Definition
Table page 3 of 3
**The user sets these entries plus <ADAPT TUNE> to <On, Off>.
Setting
Display
Filter
Seconds
Ctrl Gain
Manual
**
**
Very Slow
120
2.0
Slow
90
4.0
Moderate
60
8.0
Normal
45
15
Aggressive
30
30
Very Aggressive
20
50
Содержание K-Vision
Страница 6: ...Page 6 Docu No 0590020601 EN Rev 1 6 0 ...