25
Save/Load Threshold
All Threshold & Control settings can be saved or loaded here.
Selecting Save Threshold Settings saves all current settings.
Selecting Load Threshold Settings loads all settings from the saved file.
Selecting Load Default Threshold resets all threshold settings to the default values XXXX
f3.1.
Version Info
Displays the current firmware version.
3�2�2 Chassis Control and Alarm Threshold Setting
Provides operational and threshold settings for the PXIe-62780, including trigger bus, PXIe
link, target temperature, and fan mode, and threshold settings for DC voltage, temperature,
and cooling fan speed.
Trigger Bus
PXI trigger bus routing settings are shown. Between trigger bus segments - TRIG BUS A (slot
1st to 6th), B (slot 7th to 12th), and C (slot 13th to 18th), each PXI trigger bus line can be
individually configured as different routing topologies. Trigger bus routing settings can be
easily saved as templates and loaded quickly.
Figure 3-3: PXI Trigger Routing Interface