PCIe/PXIe-6301 Series |
| 37
➢
You can use three different kinds of triggers in this program as mentioned in
this
chapter.
Start Trigger
and
Reference Trigger
can be set by
Trigger Mode
. For
Re-
Trigger
can be used by changing the numbers in
Retrigger Count
.
◼
Now the
Trigger Mode
is “
Reference
”
, and the PreTrigger Samples is 10.
Click
Start
to begin the data acquisition, the result is shown below:
Figure 23 Retrigger in Reference Trigger Mode
➢
Because the measured waveform is a straight line, the effect of reference trigger
can not be seen clearly.
◼
Now change the mode of trigger to
Retrigger
through giving
Retrigger Count
the
number 5 and click
Start
. A message will appear in the lower left corner:
“
Samples
acquired: 400/500
”.
Figure 24 Retrigger Complete State
➢
It shows the acquisition process through every trigger signal.