JYE DSO 082 Скачать руководство пользователя страница 1

 

                                                    DN082-02v02 

JYE Tech                                                                  - 1 -                                                               

www.jyetech.com

 

 

LCD Digital Storage Oscilloscope 

Manual of Operation   

Applicable Models: 08201/08201B, 08202/08202B 

 

1.

 

Packing List 

 

Items 

08201/08201B 

08202/08202B 

082 Digital Storage Oscilloscope 

1   

AC/DC Power Adapter 

BNC Probe 

 

Operating Manual 

 

2.

 

Precautions 
1)

 

Do  not  use  a  supply  voltage  higher  than  the  specified  maximum  input  voltage  of 

9-12VDC  to  the  instrument,  as  this  may  damage  it  and  also  invalidate  your 

warranty. 

2)

 

Do not attempt to directly measure mains power supply without using a step down 

transformer.    DO NOT EXCEED 50V MAX   

3.

 

Panel Description 

 

 
The  photo  above  shows  the  screen  and  various  front  panel  controls.  They  are  explained 
respectively below. 

Screen 

1)

 

Vertical position indicator

 

 the small triangle on the left border of the grid

 indicates the 0 volt input 

level. Its position can be changed up or down, by pressing [VPOS] and turning the adjustment knob. 

2)

 

Trigger  level  indicator

 

  the  small  triangle  on  the  right  border  of  the  grid 

  shows  the  threshold 

voltage  of  trigger.  It  is  triggered  when  the  input  signal  level  crosses  the  threshold  voltage  level;  the 

trigger level is referenced to the input signal ground. 

3)

 

Window  position  indicator

 

  indicates  the  displayed  portion  of  sampled  memory.  The  distance 

between  the  two  short  vertical  bars  at  the  bottom  represents  the  whole  length  of  sampled  memory, 

which is usually much longer than the screen can display. So at any given moment the screen can only 

display  a  portion  of  the  sampled  data.  The  window  position  indicator  shows  which  portion  is  being 

Fig 1 

Содержание DSO 082

Страница 1: ...d respectively below Screen 1 Vertical position indicator the small triangle on the left border of the grid indicates the 0 volt input level Its position can be changed up or down by pressing VPOS and...

Страница 2: ...h blocks the DC component of input signal When this switch is set to GND the input signal is disconnected and oscilloscope input is connected to ground Vertical Sensitivity Select Switches There are t...

Страница 3: ...of oscilloscope It serves two purposes 1 Test Signal output 2 External Trigger input The function of M F T is selected by LEVEL key and indicated by the small letter at the right of trigger mode indic...

Страница 4: ...ther depending on type of transistor used You should see a waveform similar to that shown in Fig 4 3 Select AUTO trigger mode and change the trigger level You should be able to observe that the wavefo...

Страница 5: ...ry power Power Off To power off the oscilloscope push down the adjustment knob and hold it for about 3 seconds The oscilloscope will enter stand by mode where most of circuits are powered off Only key...

Страница 6: ...d in on the screen 5 Press the LEVEL button then HOLD Scope screen will be sent to PC as a bitmap file Using the External Trigger 1 To Select the trigger source Press LEVEL to highlight the trigger le...

Страница 7: ...put Voltage 50Vpp for 1X probe Couple Range DC AC GND Horizontal Max Real time Sample Rate 50MSPS Time base Range 0 2us Div 10minute Div Record Length 2000 16000 points user selectable in steps of 200...

Страница 8: ...refurbished parts ii replace the oscilloscope with a new or refurbished one or iii refund to you all or part of the purchase price of the oscilloscope All replaced parts and oscilloscopes for which a...

Отзывы: