350
JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
17.2.6
Exit safe mode
When this command is sent, the MIS/SMC switches back to normal mode.
Block description
17.2.7
Write to flash
This command writes the register values to flash memory. The values will then be re-
tained after a power down. The command will only work if the motor is in “Safe mode”
After the command is executed, the motor will reset. The response will only be trans-
mitted if the command failed, e.g. if the motor is not in safe mode.
Block description
17.2.8
Reset controller
This command resets the MIS/SMC. No response will be transmitted from the MIS/SMC.
Block description
Controller sends
MIS/SMC response
<ExitSafe><Address><End>
<Accept>
Block Name
Protected
Example
Description
<ExitSafe>
No
55h,55h,55h
Exit safe mode command
<Address>
Yes
07h,F8h (Address 7)
The address of the MIS/SMC
<End>
No
AAh, AAh
Command termination
<Accept>
No
11h, 11h,11h
Accept from MIS/SMC
Controller sends
MIS/SMC response
<WriteFlash><Address><End>
<Accept>
Block Name
Protected
Example
Description
<WriteFlash>
No
56h,56h,56h
Write to flash command
<Address>
Yes
07h,F8h (Address 7)
The address of the MIS/SMC
<End>
No
AAh, AAh
Command termination
<Accept>
No
11h, 11h,11h
Accept from MIS/SMC
Controller sends
MIS/SMC response
<Reset><Address><End>
None
Block Name
Protected
Example
Description
<Reset>
No
57h,57h,57h
Reset command
<Address>
Yes
07h,F8h (Address 7)
The address of the MIS/SMC
<End>
No
AAh, AAh
Command termination
Содержание MIS17 Series
Страница 56: ...56 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Страница 57: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 57 3 Functional Safety ...
Страница 76: ...76 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Страница 77: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 77 4 Using MacTalk ...
Страница 165: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 165 7 Error Handling ...
Страница 177: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 177 8 Registers ...
Страница 235: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 235 9 Building Sequential Programs ...
Страница 266: ...266 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Страница 309: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 309 12 Modbus interface ...
Страница 313: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 313 13 Stand alone electronics ...
Страница 318: ...318 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Страница 319: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 319 15 Technical Data ...
Страница 325: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 325 15 5 Torque Curves ...
Страница 338: ...338 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 15 8 Trouble shooting guide ...
Страница 340: ...340 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 16 1 Cables ...
Страница 345: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 345 17 Appendix ...
Страница 355: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 355 18 Declarations ...
Страница 362: ...362 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 18 4 TÜV certificate ...