208
JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
8.2.52
Afzup_ConfMax
Description: The maximum confidence limits for analogue inputs are set and read back using this reg-
ister in combination with the read and write ‘command’ registers 100 and 101.
If a new raw sample value is larger than the value in this register, it is simply discarded and
the filtered input value in registers 81-88 will not change. A value of 4095 in this register
will effectively disable the maximum confidence check.
8.2.53
Afzup_MaxSlope
Description: The maximum slopes per sample for analogue inputs are set and read back using this
register in combination with the read and write ‘command’ registers 100 and 101.
If a new raw sample value on an analogue input lies farther from the previous filtered val-
ue in registers 81-88, the new sample will be modified to lie at most MaxSlope units from
the filtered value. This is used to suppress noise and limit acceleration. Note that the
value is optionally filtered after being slope limited, in which case the effective slope lim-
itation will be divided by the filter ratio. A value of 4095 will effectively disable slope lim-
itation.
8.2.54
Afzup_Filter
Description: The final filtering of new samples on the analogue inputs can be selected using this regis-
ter in combination with the read and write ‘command’ registers 100 and 101. The final
filtered value results from taking Filter/64 of the new sample plus (64-Filter)/64 of the old
value and storing the result in registers 81-88. A value of 64 effectively disables this
filtering, so the new sample simply replaces the old value.
8.2.55
FilterStatus
Description: This register contains status bits for the analogue input filters. The lowest eight bits hold
confidence errors for each of the eight inputs, while the highest eight bits hold the status
of their slope errors.
The filter status is updated each second. The confidence error bit will be set if more than
half of the samples within the last second fell outside either of the confidence limits.
The slope errors will be set if more than half of the samples within the last second were
slope limited.
Reg
Name
Size
Access
Range
Default
Unit
MacTalk name
103
AFZUP_Conf Max
32bit
R/W
1-4095
4095
1.221 mV
Confidence Max
Reg
Name
Size
Access
Range
Default
Unit
MacTalk name
104
AFZUP_ Max Slope
32bit
R/W
2-4095
4095
1.221 mV
Max Slope
Reg
Name
Size
Access
Range
Default
Unit
MacTalk name
105
AFZUP_Filter
32bit
R/W
1-64
64
64
th
of new
sample
Filter (on the Filter
setup screen)
Reg
Name
Size
Access
Range
Default
Unit
MacTalk name
106
FilterStatus
32bit
R
0-65535
0
N/A (shown
graphically)
Содержание MIS17 Series
Страница 56: ...56 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Страница 57: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 57 3 Functional Safety ...
Страница 76: ...76 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Страница 77: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 77 4 Using MacTalk ...
Страница 165: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 165 7 Error Handling ...
Страница 177: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 177 8 Registers ...
Страница 235: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 235 9 Building Sequential Programs ...
Страница 266: ...266 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Страница 309: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 309 12 Modbus interface ...
Страница 313: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 313 13 Stand alone electronics ...
Страница 318: ...318 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Страница 319: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 319 15 Technical Data ...
Страница 325: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 325 15 5 Torque Curves ...
Страница 338: ...338 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 15 8 Trouble shooting guide ...
Страница 340: ...340 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 16 1 Cables ...
Страница 345: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 345 17 Appendix ...
Страница 355: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 355 18 Declarations ...
Страница 362: ...362 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 18 4 TÜV certificate ...