170
JVL Industri Elektronik A/S - User Manual - Ethernet for MAC and MIS motors
7.3
Register access
The registers in the motor and in the module are all 32 bit (at least they are when travel-
ling through the module so special care must be taken with those registers in MAC050-
141 which originally is 16bit). To comply with the clean 16-bit Modbus standard, a 32-bit
register must be read or written as two consecutive 16-bit registers. The register ad-
dress mapping follows the normal documented register numbers but the address field
must be multiplied by two, so to read or write motor register 3, P_SOLL, use the address
6. Thereby enabling transfer of one 32 bit register, as two 16 bit registers, where the
least significant 16 bit “register” is transmitted first (see examples in section 7.2.4).
Motor registers are accessed by addressing register 0x00 – 0x1FE (for logic motor reg-
ister 0-255), and modbus register 0x200 - 0x3FE for extended motor registers (256-
511), and module registers is accessed by addressing 0x8000 – 0x807E (for logic module
register 0-64). Please find a complete list of register descriptions in the appendix:
Motor registers MAC050 - 141, page 264
Motor registers MAC400 - 4500, page 273
Motor registers MISxxx, page 292
7.3.1
Module registers.
Note:
Module parameters are not automatically saved to permanent memory after a change. The
parameters can be saved permanently by applying a “Save parameters to flash” command after-
wards.
Logic
register
no.
Modbus
address
(hex)
Modbus
address
(dec)
Read
only
Default Description
0
0x8000
32768
X
Not used
1
0x8002
32770
X
High 16 bit of MAC address (placed in low 16 bit of word)
2
0x8004
32772
X
Low 32 bit of MAC address
3
0x8006
32774
IP address
4
0x8008
32776
Net mask
5
0x800A
32778
Gateway
6
0x800C
32780
0x00
Setup bits
7
0x800E
32782
Digital outputs on module
8
0x8010
32784
Reserved for other protocols
9
0x8012
32786
Reserved for other protocols
10
0x8014
32788
Modbus timeout. 0 = timeout function disabled
11-14
0x8016
0X801C
Reserved for future use
15
0X801E
32798
Command register
16 – 31
0x8020 –
0x803E
Reserved for other protocols
32
0x8040
32832
X
Module serial no.
33
0x8042
32834
X
Module hardware version
34
0x8044
32836
X
Module software version
35
0x8046
32838
X
No. of internal motor communication timeouts
36
0x8048
32840
X
No. of retry frames to motor
37
0x804A
32842
X
No. of discarded frames to motor
38
0x804C
32844
X
Total no. of frames to motor
39-46
0x804E –
0X805C
X
Reserved for future use
47
0x805E
32862
X
Digital inputs on module
48
0x8060
32864
X
Status bits
49-63
0x8062 –
0X807E
X
Reserved for future use
Содержание MAC00-EC4
Страница 2: ......
Страница 7: ...JVL Industri Elektronik A S User Manual Ethernet expansion modules for MAC motors 7 1 Introduction ...
Страница 14: ...14 JVL Industri Elektronik A S User Manual Ethernet expansion modules for MAC motors ...
Страница 32: ...32 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Страница 33: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 33 3 EtherCAT Users Guide ...
Страница 78: ...78 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Страница 79: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 79 4 EthernetIP Users Guide ...
Страница 113: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 113 5 POWERLINK Users Guide ...
Страница 136: ...136 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Страница 137: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 137 6 PROFINET Users Guide ...
Страница 159: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 159 7 ModbusTCP IP Users Guide ...
Страница 176: ...176 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Страница 177: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 177 8 Sercos ...
Страница 224: ...224 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Страница 225: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 225 9 Module Registers ...
Страница 239: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 239 10 Using MacTalk over Ethernet ...
Страница 241: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 241 ...
Страница 252: ...252 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Страница 253: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 253 11 Examples common to all protocols ...
Страница 256: ...256 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Страница 257: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 257 12 Appendix ...