ENGLISH
E-11
Camera unit/Inside the camera
T
This is when the dome cover, inner cover and outer case is removed.
How to remove (
Steps
H
Power supply/Alarm signal cable
Note :
●
Do not use PoE together with DC 12 V power
supply. Simultaneous connection will cause
failure or malfunction.
I
[10BASE-T/100BASE-TX(PoE)] Connector
for LAN cable connection (RJ-45)
J
Strap
This sheet connects the camera unit to the dome
cover.
K
Fastening screw (x3)
This is the screw head of the ceiling mounting
bracket
Q
, which is used to embed the camera
in the ceiling.
L
[RESET] Reset button
This is a button for rebooting the camera. Press
this button and release within 5 seconds to
reboot the camera. It takes about 1 minute for
the camera to reboot. During startup, [RESET]
button is disabled.
Note :
●
Pressing the [RESET] button for 5 seconds
or longer switches the camera to the service
verification mode. Do not press the button for
5 seconds or longer.
M
[MONITOR] Monitor terminal (RCA pin)
N
Camera unit
O
Fall-prevention wire fastening hook
P
Fall-prevention wire (supplied) and wire
mounting screw
Connect the camera unit
N
and the outer case
C
with the fall-prevention wire fastening screw
O
.
MAC address
P
O
X
Q
K
N
M
R
S
T
U
V
P
W
J
Y
L
Behind the camera unit
Lens section
(
Signal name
Cable color
Alarm input 1
Pink
Alarm input 2
Blue
Alarm output 1
Orange
Alarm output 2
Yellow
GND
Brown
DC 12 V power
Red
DC 12 V power supply-
Black
VN-C215_EN.book Page 11 Tuesday, March 20, 2007 1:54 PM