1-24 (No.MB574)
SECTION 4
ADJUSTMENT
4.1
CD TEST MODE
4.1.1 Set the CD TEST MODE
4.1.2 Set the CD TEST MODE 2 (Indication auto adjustment value)
4.2
ERROR HISTORY
4.2.1 Outline
EEPROM use 256byte, when an abnormal state is generated, the factor is written in EEPROM.
Worth of a history is left for each item 16 times.
ERROR HISTORY.
4.2.2 EEPROM writing
(1) EEPROM information
Press STOP [ ] button and CD play/pause [ ] button together and keep then connect AC power cord.
LCD indication [ __CD_TEST_1].
Complete the setting TEST MODE.
Assumes after the TOC reading to be effective, and (E1 ~ E3) is transmittend in order in the table at each SET
reception of remote control.
The E1 status : the adjustment value (ten kinds) based on status with [1:OK,0:NG] of bit like the HEX data.
As follows at each reception
[ ] and the toggle are displayed.
FG_ _
FEXP
FBAL
FOFS
FES_
TG_ _
TEXP
TBAL
TOFS
TES_
TAGC
FAGC
ABC2
ABC1
AGC2
AGC1
AOC1
Focus gain mantissa
Focus gain index part
Focus balance adjustment value
Focus offset adjustment value
Turbulence amplitude when focus gain is adjusted
Tracking gain mantissa
Tracking gain constant index part
Tracking balance adjustment value
Tracking offset adjustment value
Turbulence amplitude when tracking gain is adjusted
Tracking energy gain (Only ST1 :. )
Focus energy gain
Tracking balance
Focus balance
Tracking rough gain
Focus rough gain
Focus offset
E2 status
(FOCUS system self
adjustment information)
E3 status
(TRACKING system self
adjustment information)
E1 status
(self adjustment information)
Adjust value
"CD test mode 2" is released by CANCEL key to remote control.
Shifts to "CD test mode 1" (The display is returned to "__CD_TEST_1").
Clearness of test mode
All the CD test modes are made clear by the thing that the POWER key is pushed.
At LCD indication [ __CD_TEST_1] condition, press [
SET
] key of the remote controller more than 3 sec.
LCD indication change to [ __CD_TEST_2].
1
2
3
4
5
6
0x100
0x110
0x120
0x150
0x160
0x1A0
0x1B0~
1
1
1
1
1
1
When detectiong of SAFETY
error, writing SAFETY number
and AD value
Timer playback is not starting
Time out of power OFF process
Error with CD
When starting of power OFF
process
Power circuit failure.
Damege of card wire.
Missing key operation.
User operation.
Mechanical and module failure.
Damege of card wire.
Missing key operation.
Mechanical and pickup failure.
User operation.
Safety abnormal
No. & AD value
Factor of failure
Factor of failure
Factor of failure
Factor of power off
16
16
16
16
16
16
SAFETY Number
AD value
Timer playback start NG
factor
P.OFF timeout factor
CD
P.OFF factor
Other
No.
ITEM
EEP address byte Count
Value of writing
Writing condition
Guessed factor