32
Changing camera settings from remote control
This screen allows you to configure title and alarm settings.
(
●
indicates the default value)
CAMERA TITLE/ALARM
screen
Item
Setting value
Functions and settings
CAM.TITLE EDIT..
^
This item sets the title to be displayed permanently on the lower left of the
screen. A maximum of 16 characters can be set for the title.
AREA DISPLAY
●
OFF
TITLE
DIR
This item sets the area settings.
OFF
^
Settings will not be displayed.
TITLE
^
This item divides the 360° horizontal rotation area into 16 areas and allows you
to set a 16 character title in each area. The area title will be displayed when the
camera is panned manually (horizontal rotation).
[Area Display Mode Setting (Title)] (
DIR
^
This item sets the basic axis direction N (north). When the camera is panned
(horizontal rotation) manually, the 360° horizontal rotation area will be divided
into 8 areas, and N, NE, E, SE, S, SW, W, NW will be displayed respectively for
each area.
[Area Display Mode Setting (Direction)] (
ALM.TITLE SIZE
NORMAL
●
DOUBLE
This item sets the size of the title displayed during an alarm.
NORMAL:Same size as the text on the menu screen.
DOUBLE:Twice the size vertically and horizontally as the text on the menu
screen.
ALM.TITLE COLOUR
●
WHITE
GREEN
CYAN
YELLOW
This item sets the color of the title displayed during an alarm.
ALARM TITLE EDIT..
^
This is the setting screen for the title displayed during an alarm.
[Remote Control Alarm Title Setting] (
ALARM INPUT..
^
This item sets the alarm input terminal.
ALARM INPUT..
This item selects the status of the image output camera during alarm input.
OFF
:Does not output images even at alarm input.
HOME :Outputs home position images during alarm input.
POS1 to POS99:
This outputs the video of the selected preset position during alarm input.
Memo
:
●
Page 35) setting is set to [ALARM IN1 to 6],
A
(B&W)
B
will be displayed and settings is disabled.
ALARM IN1 to 6
●
OFF
HOME
POS1 to POS99
POLARITY
●
MAKE
BREAK
This sets the polarity of the alarm input signal.
MAKE
:When the contact between all alarm input terminals and GND terminals
changes from open to close, the alarm will activate.
BREAK :When the contact between all alarm input terminals and GND terminals
changes from close to open, the alarm will activate.
Memo
:
●
When [ALARM INPUT] item is set to
A
OFF
B
,
A
- - -
B
will be displayed and
settings is disabled.
TK-C686E_EN.book Page 32 Tuesday, December 4, 2007 4:45 PM