22
Connecting the control signal cable
The maximum connection distance with RM-P2580 is 1200 m.
(Multiple cameras can be connected on one cable for RM-
P2580 but the total length of the cable must be within 1200 m.)
䡵
Connect the cable to the terminal block
A
Loosen screws on both sides of the terminal block with a
flathead screwdriver and remove the terminal block as
shown in the diagram below.
Memo
:
●
Inserting the tip of the screwdriver into the slit of the
terminal block will remove the terminal block easily.
B
Peel off about 4 mm of the control signal cable covering
and insert into the terminal.
C
Turn the screws on the sides and secure the control
signal cable.
D
When the control signal cable is secured, return the
terminal block that was removed in
A
to its original
position.
䡵
Overall view of control signal cable connection
Memo
:
●
We recommend the use of paired cables or twisted pair
cables used in Ethernet rather than 0.61-4-core (2 pairs)
cables.
●
Thickness of the cable is
R
0.4 mm to
R
1.3 mm.
●
Arrange the control signal cables such that the TX+ and
TX
–
signals and RX+ and RX
–
signals are pairs.
4 mm
A
B
A
D
C
Control signal cable
terminal
●
To connect correctly, connect
cables that have the same mark
as displayed on the
camera terminal and both
terminals of RM-P2580.
A B C D
Camera terminal 1
Camera terminal 2
Camera terminal 3
RM-P2580
TO CAMERA Terminal