76
Others
Troubleshooting
Symptom
Cause
Action
Video image does not
appear
Power does not turn on.
●
Are the camera and ceiling mount brackets mounted
securely? (TK-C685E/TK-C686E)
●
Are the power cables and coaxial cables connected
correctly?
●
Is the power cable thick enough?
●
Is the lens cap still attached to the camera?
●
Is the power turned on under an environment of -40 to
-20
I
●
Mount the camera and ceiling
mount brackets securely.
●
Connect the cables correctly.
●
Use a cable of the correct
thickness.
●
Remove the lens cap.
●
Maintain this status for about 2
hours until the internal heater has
warmed up.
Power is turned off but it is
disconnected once the
rotation platform operates.
●
Is there a problem with the cable between this unit
and the power unit?
(If the cable is too long or thin, the resistance of the
cable is large and the voltage will drop when the
rotation platform is operating.)
●
Is the transporting tape removed?
●
Change the power cable to one
with a low resistance
(thick and short cable).
●
Remove the transporting tape.
●
The remote control does
not work.
●
The camera does not
operate smoothly in
response to the remote
control.
●
The Pan/Tilt lever can be
operated but the menu
screen cannot be
displayed.
●
Are the settings for Setting Switch 4, 5, 8 correct?
●
Is the camera under key lock (prevent misoperation)?
●
Is the connection of the control signal cable correct?
●
Set the switches correctly.
●
Cancel key lock.
(
A
RM-P2580 Instruction Manual)
●
Connect the cables correctly.
●
appears on the screen.
(
T
T
are numeric
characters)
●
The built-in cooling fan or heater fan
(TK-C685WPE/TK-C686WPE only) is malfunctioning.
●
Take down the characters
displayed on
consult your nearby JVC dealer.
Turn off the power of this unit.