11
䡵
Camera (Interior)
I
Alarm Input 2 to 6/Alarm Output 2 cable
This is a cable for alarm input 2 to 6 and alarm output 2.
(
J
Front Mask
K
Lens
Lens cannot be replaced.
L
Dome Cover Fixing Screws (x4)
M
Dome Cover
The dome cover is a delicate object. Handle it with care.
Note :
●
It is covered with a protective sheet during shipment. Do
not remove this sheet until installation is complete.
N
Option Switch
Configure this switch when Pelco protocol is used.
O
Machine ID Setting Switch
When the communication system is RS-485 multi DROP
such as the RM-P2580 system, a machine ID will be set for
every camera. (
P
Setting Switch
This switch allows you to configure settings such as protocol
and SYNC. (
Q
Heater ON/OFF Switch
This is the ON/OFF switch for automatic control of the built-in
heater.
This product comes with a built-in heater to prevent the dome
cover from being covered with snow and frost as well as
fogging. When installing the heater at an unrequired location,
turn off the switch of the heater. Set the power of the heater
to
Q
O
N
P
J
K
L
M
Cable color
Signal Name
BROWN
Alarm input 2
RED
Alarm input 2 (COM)
ORANGE
Alarm input 3
YELLOW
Alarm input 3 (COM)
GREEN
Alarm input 4
BLUE
Alarm input 4 (COM)
PURPLE
Alarm input 5
GRAY
Alarm input 5 (COM)
WHITE
Alarm input 6
BLACK
Alarm input 6 (COM)
PINK
Alarm output 2
LIGHT GREEN
Alarm output 2 (COM)