E-14
Installation and connection
Before Adjusting the Camera
Press A and B lightly, and remove inner cover.
The MONITOR terminal is used when making various adjustments to the camera at installa-
tion.
IRIS
LEVEL Volume
75
Ω
termination
Open
Adjustment
button
Setting switch
Monitor TV
B
A
50˚
80˚
Horizontal
Lock screw
Variable
range 350˚
Vertical rotation
FOCUS ADJ.
Switch
Remove the inner cover, and adjust the camera angle of the zoom and focus positions. Mount
the inner cover.
LENS
CENTER
Horizontal rotation
(adjustable range: 350°)
1.
Loosen the horizontal LOCK screw.
2.
Holding the both tilt lock screws, rotate
horizontally.
3.
Tighten the horizontal LOCK screw.
Vertical rotation
(adjustable range: +80°, –50°)
1.
Loosen the tilt lock screws.
2.
Holding the rotation levers, rotate
vertically.
3.
Tighten the tilt lock screws.
Image inclination
(adjustable range: ±15°)
Manipulate the rotation levers to adjust
the inclination of the image.
Adjusting the Lens and Camera Angle
Inner cover
C
Tilt lock screws
After making camera adjustments, attach the inner cover to ensure that the tilt lock screws fit
into the holes (C).
03_e_TK-C205VPU_02_20_e.p65
05.4.22, 9:38 AM
14