Fill the conduit hole and mounting holes with sealing agent and insert the silica gel before
mounting the camera unit to the base.
Mount the Camera unit to the Base
Sealing agent
Sealing
agent
���
���
Silica gel
Lug plate
Mount the camera unit to the base
Align
���
and
���
on the camera with
���
and
���
on the base.
CAUTION
Not filling the holes completely with seal-
ing agent may cause moisture to enter,
clouding the lens and dome cover as a
result. Be sure to completely close the
holes.
Fill using sealing agent
Completely fill the conduit hole using sealing
agent. Also fill the mounting holes when not
in use.
MEMO
The sealant should be GE silicone or
equal.
Insert the included Silica gel
Insert the provided silica gel in the Base inte-
rior and hold using the lug plate.
MEMO
Always replace the silica gel when recon-
necting/resetting during repair or mainte-
nance.
When replacing, use:
Service parts No. LW40500-001A
CAUTION
• When performing installation under
raining conditions, take caution as not
to allow rain to enter inside the unit.
• Always use the provided silica gel. When
not using the silica gel, the dome cover
of the camera lens may cloud as a result.
• If the camera angle is not adjusted at
installation, insert the silica gel inside
the unit after adjustment. The effects of
the gel diminish with prolonged
exposure to air.
03_e_TK-C205VPU_02_20_e.p65
05.4.22, 9:37 AM