E-11
English
8 mm
2 mm
Pipe
3.
12mm (
15
/
32
")
or less
CAUTION
• Since the camera unit and dome cover will be in a suspended state from the base by the
safety cable, the camera unit and dome cover will also move when mounting the base to
the pipe. Facing the camera lens to the dome-cover side at this time may cause scratch-
ing of the lens. Make sure the dome cover and camera unit are facing opposite sides.
• When screwing in the pipe into the conduit hole, do not screw in more than 12mm (
15
/
32
")
to prevent damage to the pipe interior.
4.
CAUTION
Check to make sure there is no gap be-
tween the ceiling and base.
Seal tape
Safety cable
5.
6.
3.
Connecting the safety cable
To prevent dropping, connect the unit
to a sturdy location (ceiling slab or chan-
nel) and safety cable.
4.
Wrap seal tape
Wrap the screw section of the pipe with
at least 2 rolls of seal tape.
Wrap the seal tape where the pipe-hole
screws and pipe screws meet.
5.
Mount the base to the pipe
Screw in the base to the pipe by turning
it clockwise.
(Conduit hole: 3/4-10 UNC)
When Installing the Camera Using the
Conduit Hole (side) (
page 16)
When Installing the Camera Using the
Electrical Box (
page 17)
When installing the camera to a ceiling
without piping (
page 18)
6.
Fix the base to the ceiling
Securely tighten using screws suitable
for the mounting holes (ø5mm (
3
/
16
")).
(Screws not included.)
CAUTION
• For the used safety cable, pay particular
caution to the length, strength, pull,
material (insulation), etc.
• Always use the M4 screws mounted on
the unit.
03_e_TK-C205VPU_02_20_e.p65
05.4.22, 9:37 AM
11