Mounting a plasma display television requires specific technical knowledge. Do not attempt to mount the unit by yourself.

Please be aware that screw holes and anchor bolts will remain in the wall surface if the Wall Mounting Unit is removed

after having been mounted to the wall.

Long-term use of the plasma display may result in discoloration of the wall surface due to heat/air emitted by the display.

Wall Mounting Unit

Assembly and Mounting Instructions

For Assembly By Authorized Service Personnel Only

Consult authorized service personnel for the installation of this unit. Installation

instructions must be followed precisely in order to prevent accidents. We are

selling this product with the understanding that it will be assembled and installed

by properly trained and qualified service personnel.

We are not liable for any damage caused by faulty assembly,
faulty wall mounting, insecure wall mounting, misuse,
alterations, or natural disasters.

This unit weighs approx. 60 kg (approx. 132 lbs.) including plasma display

monitor. Incomplete or inadequate mounting of this unit to the wall may cause

it to fall down, resulting in potentially fatal accidents.

Please consult authorized service personnel for the installation of this unit.

Danger

Содержание RK-C42WBT3

Страница 1: ...ll Mounting Unit Assembly and Mounting Instructions For Assembly By Authorized Service Personnel Only Consult authorized service personnel for the installation of this unit Installation instructions must be followed precisely in order to prevent accidents We are selling this product with the understanding that it will be assembled and installed by properly trained and qualified service personnel W...

Страница 2: ... heavy objects on the power cord as damage to the power cord may result causing fire or electric shock This unit does not come with anchor bolts for securing it to walls etc Be sure you have materials on hand as appropriate for the mounting location Safety Precautions Improper handling in disregard of these notices may result in danger of death or bodily harm Improper handling in disregard of thes...

Страница 3: ...isture may lead to fire or electric shock Do not install the Wall Mounting Unit near the blower or air inlet of an air conditioner Do not install the unit in a location with a large amount of dust soot or cigarette smoke as this may lead to fire Do not block the ventilation holes and be sure to leave sufficient space around the unit for ventilation Inadequate ventilation may cause the unit interio...

Страница 4: ...g installation i e exposed or severed wiring may result in fire or electric shock Conduct the work with adequate working space Damage or bodily injury may result from working under unsuitable conditions Avoid mounting this unit in areas where there is electrical wiring or water pipes as fire or electric shock may result Names of Parts Components List q Frame 1 w Wall Mounting Unit 1 Tools Required...

Страница 5: ...med before attaching the plasma display 1 Take the left and right Frame Fastening Screw Components and remove the Fastening Screw Spacer Ring Flat Washer and Spring Washer These Frame Fastening Screws Spacer Rings Flat Washers and Spring Washers will be used when attaching the plasma display to the Wall Mounting Unit Be sure to keep them in a safe place Frame Fastening Screw Spring Washer Flat Was...

Страница 6: ...lar material should be laid out to prevent damage to the plasma display during attachment to the unit Fasten all bolts and screws securely Failure to do so may cause the plasma display and Wall Mounting Unit to fall down causing potentially fatal accidents Improper positioning installation of the Wall Mounting Unit on the wall may cause the unit to fall down Check the structure material and streng...

Страница 7: ...injury Instructions for Assembly cont d Caution 4 Attach the plasma display to the Wall Mounting Unit This task must be performed by at least two persons Insert the Rotation Jaw of the Frame q attached to the plasma display securely into the Rotation Shaft Screw Component of the Wall Mounting Unit then raise up the plasma unit on this axis and push it into place it should lock with a clicking soun...

Страница 8: ...and fasten them securely using a screwdriver Confirm that all of the parts are securely fastened and do not rattle and loose Frame Fastening Screw Spring Washer Flat Washer Spacer Ring Avoid inserting fingers into the gap between the Frame and the Wall Mounting Unit when putting these together as fingers will get trapped causing injury Instructions for Assembly cont d Caution Frame Fastening Screw...

Страница 9: ...stment Lever when the desired angle setting is reached Caution Grip the plasma display firmly while adjusting the angle as the display could tip over and cause injury 2 Fix the Angle Adjustment Lever Once the plasma display has been set at the desired angle fasten the Angle Adjustment Lever with the screw M5X20 r Check to make sure that the Angle Adjustment Lever is securely fastened and the plasm...

Страница 10: ...ews are not securely fastened the plasma display may fall causing potentially fatal injury Grip the plasma display as you adjust the angle as the plasma display may tip over and cause injury 20 Grip the plasma display firmly while connecting the power cord system cables as the display may tip over and cause injury Caution Caution Caution 1 Check the Frame Fastening Screws Check that the two Frame ...

Страница 11: ... the power cable or system cables Failure to do so may allow it to tip over potentially causing injury Caution 4 Pull the plasma display forward Brace the bottom of the plasma display and push up the heads of the screws at the left right of the Frame Attachment Lever Screw component at the bottom of the Wall Mounting Unit until the screws come into contact with the Frame The plasma display can now...

Страница 12: ...Instructions for Assembly cont d 6 Fix the Plasma Display to the Wall Mounting Unit Push the bottom of the plasma display toward the Wall Mounting Unit to securely fasten the display to the Wall Mounting Unit Then fasten the Rotation Shaft Screw Component at the bottom left right of the Wall Mounting Unit with the Rotation Shaft Screws and the Spacer Rings This task must be performed by at least t...

Страница 13: ...Fasten the Angle Adjustment Lever Once the angle of the plasma display has been set fasten the Angle Adjustment Lever with the Screw M5X20 r Check to make sure that the lever is securely fastened and the plasma display does not rattle Instructions for Assembly cont d Grip the plasma display firmly as you adjust the angle as the display may fall forward and cause injury r Screw M5X20 x 1 Caution An...

Страница 14: ...ustment Lever Lock Screw before performing this task This task must be performed by at least two persons Instructions on Removing the Plasma Display Danger 2 Confirm that the Frame Rotation Shaft Screws at the left and right bottom of the Wall Mounting Unit are securely fastened Angle Adjustment Lever Angle Adjustment Lever Lock Screw Rotation Shaft Screws ...

Страница 15: ...rew Components at the upper left and right of the Wall Mounting Unit 4 Push up the heads of the screws in the Frame Attachment Lever components at the bottom left and right of the Wall Mounting Unit until they come into contact with the Frame Then tilt the plasma display 90 forward and without changing the inclination of the plasma display pull the display out horizontally Frame Fastening Screws F...

Страница 16: ... 170 131 60 120 568 120 180 470 400 13 13 13 13 130 340 110 20 160 20 50 110 4 R10 4 R10 6 R 1 0 6 R 1 0 E F 2 φ8 E Section Details F Section Details E Section F Section VICTOR COMPANY OF JAPAN LIMITED 2004 VICTOR COMPANY OF JAPAN LIMITED External Dimensions Mass 10 kg Angles of Inclination 0 5 10 15 20 Units in millimeters 42 inch Display Outer edge Wall Mounting Holes RK C42WBT3 INST 0405 A ...