Introduction (continued)
EN
7
8
Ceiling Mount (Terminal Side)
A
Safety Wire
Hang this wire to the Fastening Hook for Safety Wire
S
.
B
[VIDEO OUT] Coaxial Cable Terminal
Output terminal of a composite video signal (1 V(p-p)) with
an output impedance of 75
K
, to be connected to a
switcher, etc.
C
[AC24V
H
INPUT] AC 24 V Input Terminal
Connect to a AC 24 V power supply.
D
Safety Wire Mounting Hole
To prevent the camera from falling down, pass the wire from
the ceiling slab or channel to this hole.
E
[ALARM IN / OUT] Alarm Input/Output Terminals (J502)
Terminals for alarm input and output. (
A
pg. 17)
F
Locking Screw
For fastening the camera body. Ensure to fasten the
Camera Clamping Bracket
P
using this screw.
G
[CONTROL] Control Signal Terminal (J501)
Connect this to the remote control unit (RM-P2580).
H
Cover
This is a protection cover. Cut a slit in the rubber cap
attached to the cover when wiring cables. When connecting
cables to the ceiling mount, ensure to do so by running the
cables through the Cover
H
. (
A
pg. 16)
I
Cover Fastening Screw
This is used for fastening the Cover
H
and the ceiling
mount.
To remove Cover
H
, do so by unfastening this screw.
Name and Function of Parts
A
B
C
I
H
G
F
E
D
Pin No.
Signal Name
Displayed As
1
Alarm
OUT +
2
Alarm Output -
OUT -
3
Alarm Input
IN
4
GND
GND
5
^
RESERVED
Pin No.
Signal Name
Displayed As
1
TX +
2
TX -
3
RX +
4
RX -