EN
25
Setting Up the Camera Using RM-P2580 (continued)
AF FOR IR
When in the B&W mode, this camera is sensitive to both visible and near-IR lights. As such,
images may become out of focus upon switching from the Color to B&W mode, depending
on the type of light source used. Set to ON in this case to adjust focus automatically.
OFF : Disabled.
ON :
Enabled.
OFF
TILT LIMIT
Use this to set the range of Tilt (vertical) operation during manual operation. Setting this will
not affect preset positions or Auto Trace and Auto Patrol operations. When this is set to 10°,
the tilt range will be between 10° and 90°, and operation between 0° and 9° will be disabled.
[Set values: OFF, 1° to 10°]
MEMO
●
When the camera is moved by an operation that overrides the Tilt Limit into a region outside the tilt
range, the camera will function as follows when a manual Tilt operation is performed.
• Tilt operations can be freely performed outside the tilt range until the camera enters the valid range again.
• Upon entering the valid range, Tilt operation will only be possible within the Tilt Limit that has been set.
5°
M. PAN LIMIT..
Use this to set the range of Pan (horizontal) operation during manual operation. Setting this
will not affect preset positions or Auto Pan, Auto Trace and Auto Patrol operations.
A
MANUAL PAN LIMIT Setup
B
(
A
pg. 32)
[Set values: OFF, ON]
OFF
AUTO RETURN..
Camera will be automatically restored to the mode as set in
A
MODE
B
if manual operation of
the camera is not performed over the interval as specified in
A
TIME
B
.
8
CAUTION
This feature will not function properly if the model name on the serial number plate of RM-
P2580 is not stated as an RM-P2580(A) product.
MODE
This is used to set the action upon Auto Return.
OFF
: Do not perform Auto Return.
HOME
: Return to home position.
A. PAN KEY
: Restores action set by the
A
RM. A. PAN KEY
B
. (
A
pg. 29)
A. PATROL KEY
: Restores action set by the
A
RM. A. PATROL KEY
B
. (
A
pg. 29)
MEMO
●
When using this feature, set the DIP SW4 at the back of RM-P2580 to
A
ON
B
.
OFF
TIME
Use this to set the time interval before performing Auto Return.
[Set values: 1 min, 2 min, 3 min, 5 min, 10 min, 20 min, 30 min, 60 min]
MEMO
●
This item will be displayed as "- - -" when the
A
MODE
B
item is set to
A
OFF
B
and setting is not possible.
1 min
Item
Function/Set Value
Initial
Value