Connections & Installation (continued)
Switch Settings
Set the switches on the Ceiling Mount before installing the camera. Settings vary according to
configuration of the system used.
8
Setting switches
R
RESERVED (Switches 1, 2, 3)
These switches must be set to OFF.
R
PROTOCOL (1) (Switch 4)
Selects whether a single camera or multiple cameras are
controlled in a system.
Set PROTOCOL(1) to Multi drop when connecting multiple
cameras in series.
(Initial setting: OFF)
When set to Multi-drop, be sure to set the Machine ID of
each camera.
R
PROTOCOL (2) (Switch 5)
Set this switch according to the communication protocol
used when controlling the cameras.
(Initial setting: OFF)
R
SYNC (Switch 6)
When this switch is set to ON, the vertical sync of the
camera becomes locked to the frequency of the AC power
line.
(Initial setting: OFF)
(LL mode : TK-C625E : 50Hz ONLY
TK-C625U : 60Hz ONLY)
R
RESERVED (Switch 7)
This switch must be set to OFF.
R
RX TERM (Switch 8)
This switch sets whether or not the section between control
signal terminals RX + and RX - is to be terminated (with a
resistance of 110
K
).
(Initial setting: Terminated (110
K
))
When the system in which this camera is used is a
multidrop system (RS-485 system), set only the camera
located at the extreme end of the control signal cables to
A
Terminated
B
and set the other cameras to
A
Open
B
.
A
Machine ID Setting Switch
B
(
A
pg. 14)
Setting not required.
Set all to OFF.
Switch 1 :
Invalid (Set to OFF)
Switch 2 :
Invalid (Set to OFF)
Switch 3 :
Invalid (Set to OFF)
Switch 4 :
PROTOCOL(1)
Switch 5 :
PROTOCOL(2)
Switch 6 :
SYNC
Switch 7 :
Invalid (Set to OFF)
Switch 8 :
RX TERM
1
ON
2
3
4
6
7
8
5
PROTOCOL (1)
Switch 4
Point-to-point
OFF
Multi-drop (when using the RM-P2580)
ON
PROTOCOL (2)
Switch 5
Duplex (when using the RM-P2580)
OFF
Simplex
ON
SYNC
Switch 6
INT
OFF
LL
ON
RX Termination
Switch 8
Terminated (110
K
)
ON
Open
OFF