KS-FX321
1-12 (No.49771)
SECTION 3
Adjustment method
Test Instruments reqired for adjustment
1. Digital osclloscope(100MHz)
2. Frequency Counter meter
3. Electric voltmeter
4. Wow & flutter meter
5. Test Tapes
VT724 ....................... for DOLBY level measurement
VT739 ............ For playback frequency measurement
VT712 .... For wow flutter & tape speed measurement
VT703 ..................... For head azimuth measurement
6. Torque gauge .................... Cassette type for CTG-N
(mechanism adjustment)
Measuring conditions(Amplifier section)
Power supply voltage .............. DC14.4V (10.5 - 16V)
Load impedance
........... 4
Ω
(2Speakers connection)
Line out ............................................................ 20
Ω
k
Standard volume position
Balance and Bass,Treble volume .Fader
:Center(Indication"0")
Loudness,Dolby NR,Sound,Cruise:Off
Volume position is about 2V at speaker output with
following conditions.Playback the test tape VT721.
AM mode
1,000kHz/62dB,INT/400Hz,30%
modulation signal on recieving.
FM mono mode
97.9MHz/66dB,INT/400Hz,22.5kHz
deviation pilot off mono
FM stereo mode
1kHz,67.5kHz dev. pilot7.5kHz dev.
Output level
0dB (1
µ
V, 50
Ω
/open terminal)
Frequency Band
FM
87.5-107.9MHz
AM
530-1710KHz
Extension cord
: EXTKSRT002-6P