No. 52076
25
AV-20N83
AV-21D83
DEFLECTION CIRCUIT ADJUSTMENTS
[SUB MENU 3. DEF]
1. VER. SLOPE
–32 — +31
0
0
0
0
—
2. VER. HEIGHT
–32 — +31
+31
+31
0
0
—
3. VER. POSITION
–32 — +31
0
0
0
0
—
4. VER. SCURVE
–32 — +31
–21
0
-21
0
—
5. HOR. POSITION
–32 — +31
0
0
0
0
+7
6. HOR. WIDTH
–32 — +31
0
0
0
0
—
7. EW-PIN
–32 — +31
0
0
0
0
—
8. EW-TRAPEZ
–32 — +31
0
0
0
0
—
9. UP CORNER
–32 — +31
0
0
0
0
—
10. DW CORNER
–32 — +31
0
0
0
0
—
11. HOR. PARALL
–32 — +31
0
0
0
0
—
12. HOR. BOW
–32 — +31
0
0
0
0
—
13. V.ZOOM
–32 — +31
+2
–1
+7
+9
—
Item
Measuring
instrument
Test point
Adjustment part
Description
Adjustment
of
V. SLOPE
Signal
generator
Remote
control unit
1. VER. SLOPE
1. Receive a PAL circle pattern signal of vertical frequency 50Hz.
2. Select
3. DEF
from the SERVICE MENU.
3. Select
1. VER. SLOPE
with the MENU
&
/
^
key.
4. Set the initial setting value of
1. VER. SLOPE
with the MENU
*
/
T
key.
5. Adjust
1. VER. SLOPE
to make “
A = B
” with the MENU
*
/
T
key.
B
A
Blanking
line
Adjustment
of
V. POSITION
Signal
generator
Remote
control unit
3. VER. POSITION
6. Select
3. VER. POSITION
with the MENU
&
/
^
key.
7. Set the initial setting value of
3. VER. POSITION
with the MENU
*
/
T
key.
8. Adjust
3. VER. POSITION
to make “
A = B
” with the MENU
*
/
T
key.
(to be continued)
The setting (adjustment) using the remote control unit is made on the basis of the initial setting values.
The setting values which adjust the screen to the optimum condition can be different from the initial setting values.
A
B
Note:
Proceed to the following adjustment after having completed the adjustments of SUB BRIGHT and SUB PICTURE.
[COMPRESS (16:9) : OFF, fv: 50Hz mode]
Initial setting value
Variable range
COMPONENT
DVD (50Hz)
50Hz
COMPRESS(16:9)
Setting
(Adjustment)
item
60Hz
4:3
50Hz
60Hz