12. REPAIR, MAINTENANCE AND WITHDRAWAL FROM SERVICE

The  applied  rolling  bearings  of  the  fan  do  not  require  a  periodical  lubrication.  However,  it  is 

recommended to check periodically a condition of the motor bearings (the rotor of the fan should 

rotate freely without excessive backlashes and knocks).

When the noise level of the unit operation is increased it is necessary to check up the correctness of 

fastenings of the fan and the whole unit.

The rotor blades should be cleaned with a damp cloth after removing the protective net not to allow 

unbalancing the rotor.

Do not use high pressure washers to clean the fan.

In case of any disturbances in the unit operation it is necessary to contact with the installer or the 

service.

All  repair  and  maintenance  works  should  be  executed  when  voltage  is  off.  The  unit 

should be protected against an accidental activation by other persons as well.

The heater dust contamination state should be checked up periodically. In case of excessive dust 

accumulation the heater should be blown through with compressed air.

The excessive heater contamination reduces the heating power and air efficiency of the 

unit.

After withdrawal from service the unit should be passed over to the specialized collection point of 

recyclable materials.

Содержание TROPIC-1

Страница 1: ...883 56 09 POLAND I CONTACTS II ORIGINAL INSTRUCTION MANUAL III WARRANTY TERMS AND CONDITIONS IV UNIT STARTUP REPORT V INSPECTION AND MAINTENANCE DOCUMENT VI SERVICE NOTIFICATION VII LIST OF SUBASSEMB...

Страница 2: ...com pl I CONTACTS Szyma ski Nowakowski General Partnership 31 Lubelska Str 08 500 Ryki phone 48 81 883 56 00 fax 48 81 883 56 09 POLAND Export department mob 48 502 087 841 mob 48 664 465 243 export j...

Страница 3: ...3 www juwent com pl II ORIGINAL INSTRUCTION MANUAL TROPIC HEATING UNITS Size 1 2...

Страница 4: ...EVICE DESCRIPTION 5 4 TECHNICAL DATA 6 5 TRANSPORT 6 6 SAFETY RECOMMENDATIONS 7 7 MOUNTING 8 8 WATER INSTALLATION 9 9 ELECTRICAL INSTALLATION 10 10 AUTOMATICS 11 11 DEVICE STARTUP 14 12 REPAIR MAINTEN...

Страница 5: ...way that they are completely vented both operating in the horizontal and vertical position The unit includes axial fan mounted on the rear wall of the unit with a net protecting the rotor I or II row...

Страница 6: ...ustic pressure level taking dispersion factor of compartment A 50m2 and directivity factor Q 2 at the distance of 5m into consideration operational noise level of the unit of the size 2 acoustic press...

Страница 7: ...idden Note for the user The mounting or use of the heating and ventilation unit against the instruction manual makes the threat of unit damage creates the hazard to persons and property and causes the...

Страница 8: ...mounting console is used to install the unit on the wall The length of the bolts fastening the unit to the console max 20mm TROPIC 1 Side view Top view TROPIC 2 Side view Top view The units can be su...

Страница 9: ...se cut off valves upstream and downstream the unit to enable its dismounting without the necessity to drain the supply installation The solenoid valves should be connected in the heating medium supply...

Страница 10: ...a service switch WS and overload and short circuit protection devices in the supply and control box into consideration The lack of required motor safety devices and non connection of thermal contact T...

Страница 11: ...rs of the fan The transformer 5 step rotational speed controllers ARW 1 230V 50Hz allow controlling the air delivery and thermal power The individual rotational speed steps are selected manually Contr...

Страница 12: ...ans of controller RT or on off by means of thermostat TP or TPP are used for a direct installation on the valves Therefore a position protrusion of the servomotor stem is proportional to the value of...

Страница 13: ...of the TROPIC units Fig 2 Electric connection diagram without automatics Fig 3 Electric connection diagram with revolution controller Fig 4 Electric connection diagram with automatics revolution cont...

Страница 14: ...n and unit casing check up the correctness of the electric connection of the motor To switch on the unit it is necessary to open the valves of heating medium switch on the current supply to the electr...

Страница 15: ...ve net not to allow unbalancing the rotor Do not use high pressure washers to clean the fan In case of any disturbances in the unit operation it is necessary to contact with the installer or the servi...

Страница 16: ...in the instruction manual 2 reliability of connections on electric terminals 3 parameters of the mains improper parameters of the mains lack of three phases in three phase motors fan motor is damaged...

Страница 17: ...damages and aleatory damages or damages caused by the atmospheric factors b damages occurred as a result of non observance of typical rules or the rules required by the instruction manual related to...

Страница 18: ...p name and signature Motor current A User s representative stamp name and signature Remarks V INSPECTION AND MAINTENANCE DOCUMENT Date of inspection Executor of inspection stamp name and signature Ser...

Страница 19: ...y No Year of production Startup executed by Description of defect NOTE AFTER COPYING AND FILLING IN SEND THE NOTIFICATION BY FAX OR EMAIL TOGETHER WITH A COPY OF THE STARTUP REPORT JUWENT Company acce...

Страница 20: ...EMBLIES INSTALLED IN THE UNIT No Name of subassembly 1 Axial fan with single phase motor 2 Metal louvre I row heat exchanger 3 Metal louvre II row heat exchanger mark proper box corresponding with the...

Отзывы: