background image

1.

Read all instructions.

2.

Do not conceal or extend exposed con-
ductors through a building wall.

3.

To reduce the risk of fire and burns, do
not install this lighting system where the
exposed bare connectors can be shorted
or contact any conductive materials.

4.

To reduce the risk of fire and overheat-
ing, make sure all connections are tight.

5.

Do not install any luminaire closer than 6
inches (15.25cm) from any curtain, or
similar combustible material.

6.

Turn off electrical power before modify-
ing the lighting system in any way.

7.

This transformer is intended for use with
Juno Trac 12 Series or Trac 12/25
Series or Flex 12 Series low voltage
lighting system only and is optimized for
a non-resistive LED load.

8.

Install transformer on a wall or other ver-
tical surface.

9.

Do not install in confined or unventilated
areas that may entrap heat.

10.

Do not allow transformer to come in con-
tact with insulation.

11.

Do not install in wet or damp locations or
outdoors.

12.

Do not install in a non-accessible loca-
tion. Units are equipped with a manually
resettable circuit breaker that will trip in
the event of a short circuit or overload
condition.

13.

Use only 10 or 12 gauge wire to connect
the transformer output to the Trac.

14.

TL575 series transformers should be
dimmed only with dimmers specifically
designed for use with magnetic transform-
ers. When used in conjunction with a non-
resistive LED load, these transformers
should be dimmed using only dimmers
qualified for this application by Juno
Lighting Group as listed on Juno specifi-
cation sheet, which can be accessed at
www.junolightinggroup.com. Use of dim-
mers not qualified by Juno Lighting Group
for this application can result in flicker,
reduced dimming range and erratic per-
formance. The dimmer must only be con-
nected to the 277-volt input wires provid-
ing power to the transformer.

15.

The unit is equipped with a three input
leads: white (COM), black (277V), and
yellow (BOOST).

16.

Do not exceed 12.0V at the first lamp or
exceed the maximum rated wattage of the
transformer.

17.

Connect ground wire to the GND terminal.

18.

Applying 277 volts across the COM PRI
and 277VAC PRI input terminals will pro-
vide nominal 12 volts across the output
terminals. Applying 277 volts across the
COM PRI and BOOST PRI input termi-
nals will provide nominal 13 volts across
the output terminals. 

19.

Do not apply 277 volts across the
277VAC PRI and BOOST PRI input 
terminals.

INSTALLATION
1.

Select a mounting location for the trans-
former, taking care to observe the above
listed safety / operating instructions.

2.

Choose the appropriate wire gauge, and
determine the proper wire length and
transformer input, based on the desired
lamp load and the table on the back of this
sheet.

3.

Mount the transformer and Trac to the
desired surface. Run AC power lines to the
transformer and output wires from the
transformer to the Trac.

4.

In order to avoid nuisance tripping of the
panel circuit breaker, it is recommended
that the use of a high magnetic type circuit
breaker be selected for this and all high
power, magnetic type transformer loads.

5.

Connect the input and output wires to the
transformer per the diagram on the case,
information provided on this sheet and
local electrical codes.

6.

Connect the other end of the output wires
to the Trac Feed.

7.

Ensure that all electrical connections are
tight. This step is essential for a reliable
installation.

8.

Install the lamp fixtures onto the Trac.

9.

Apply AC power. Confirm that all fixtures
function acceptably. Measure the voltage
at the first lamp. Confirm that the voltage
is between 11.4 and 12 volts.

IMPORTANT SAFEGUARDS:

When using electrical equipment, always adhere to basic safety precautions including the following:

IMPORTANT SAFETY / OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Magnetic Remote Mounted Transformers

Single output optimized for non-resistive LED loads
TL575-20-277-BL 12 volt, 0.5W min - 20W max.
TL575-40-277-BL 12 volt, 0.5W min - 40W max.
TL575-75-277-BL 12 volt, 0.5W min - 75W max.
TL575-xx-277-BL 12 volt, 0.5W min - xxW max.

SAVE THESE INSTRUCTIONS

WARRANTY

Juno Lighting Group warrants that its products are free from defects in material and workmanship. Juno Lighting Group’s obligation is expressly
limited to repair or replacement, without charge, at Juno Lighting Group’s factory after prior written return authorization has been granted.  This
warranty shall not apply to products which have been altered or repaired outside of Juno Lighting Group’s factory. This warranty is in lieu of all
other warranties, expressed or implied, and without limiting the generality of the foregoing phrase, excludes any implied warranty of merchantabili-
ty. Also, there are no warranties which extend beyond the description of the product on the company’s literature setting forth terms of sale.

Product Services Phone (888) 387-2212

1300 S. Wolf Rd • Des Plaines, IL 60018 • Phone: 800-323-5068 • www.junolightinggroup.com

© 2009 Juno    Printed in USA        Rev 8/09    P2747   pg 1 of 2