Miniature Low Voltage Spotlights – for use with Juno T, TU,
R or V Trac systems only.
Assembly of a Low Voltage Spotlight Fixture
to Juno 12 Volt Electronic Transformer:
1.
Connect Spotlight to
Transformer
by inserting Spotlight Plug
into
Transformer
Receptacle (Figure A).
2.
Connect Spotlight to
Transformer
by inserting Adapter Disc
into
Transformer
opening and tuning clockwise until Lock Tab
engages (Figure B).
Installation of Transformer/Fixture Assembly
in Trac:
1.
Transformer
switch should be in the “Off” (to right) position
(Figure C).
2.
Insert
Transformer
Contacts into trac channel (Figure D) and
rotate
Transformer
90˚ so that arrows on
Transformer
Latch
point to polarity line on trac (Figure E). Latch pulls down to
clear
trac and “snaps” into trac section, locking complete
assembly
into position.
3.
Power to trac can now be connected and switch can be put in
“On” (to left) position.
4.
For Two Circuit Trac:
To install Spotlight and
Transformer
on the first (lower) circuit
follow steps 1, 2 and 3 above. To install Spotlight and
Transformer
on second (upper) circuit insert a thin screwdriver
under
Transformer
contact marked “P” and pull up (Figure F).
Insert
plastic contact support (Figure G) supplied with two
circuit
trac section by tipping and positioning under “P” contact.
Install
complete assembly into trac section by following steps 1,
2 and
3 above.
Dimmer Data - Solid State Transformers
12V LAMPS OPERATED BY SOLID STATE ELECTRONIC
TRANSFORMERS (
T537
) MAY BE USED
WITH
HIGH
QUALITY DIMMERS SPECIFICALLY DESIGNED FOR USE
WITH ELECTRONIC TRANSFORMERS OR A DIMMER
SYSTEM DESIGNED FOR NON-INDUCTIVE LOADS
WITHOUT FEAR OF DAMAGE TO THE TRANSFORMERS
OR DIMMER.
For further information consult your dimmer manufacturer.
INSTALLATION INSTRUCTIONS
One Lithonia Way • Conyers, GA 30012
• Phone 800-323-5068 • Visit us at www.acuitybrands.com
©201
9
Acuity Brands Lighting, Inc. Rev
8
/19
P
4734
1 of 1
Transformer
Transformer
Transformer
Transformer
Switch