Table 9: AC Power Supply LEDs
Description
State
Color
LED
Indicates one of the following:
•
Power input voltage is not within the normal
operating range.
•
No power input.
Off
Unlit
AC
Input power present and is within the normal
operating range.
Steady
Green
No DC power output or abnormal DC output.
Off
Unlit
DC
DC power output is within the normal operating
range.
On steadily
Green
Power supply unit failure.
On steadily
Amber
! (Fault)
Invalid power supply unit.
Blinking
Power supply unit is functioning normally.
Off
Unlit
NOTE:
•
If both the AC LED and the DC LED are unlit, either the AC power cord is
not installed properly or the power supply fuse has failed.
•
If the AC LED is lit and the DC LED is unlit, the AC power supply is installed
properly, but the power supply has an internal failure.
DC Power Supply
Each DC power supply weighs approximately 2.2 lb and has two independent pairs of
DC input lugs, a fan, and LEDs for monitoring the status of the power supply. The DC
power supply in the services gateway is a hot-insertable and hot-removable
field-replaceable unit (FRU) when the second power supply is installed and running. You
can install a replacement power supply without powering off the services gateway. The
DC power supply gives an output of 650 W.
shows the DC power
supply.
25
Copyright © 2019, Juniper Networks, Inc.
Chapter 1: Overview
Содержание SRX4200
Страница 1: ...SRX4200 Services Gateway Hardware Guide Modified 2019 03 20 Copyright 2019 Juniper Networks Inc...
Страница 8: ...Copyright 2019 Juniper Networks Inc viii SRX4200 Services Gateway Hardware Guide...
Страница 10: ...Copyright 2019 Juniper Networks Inc x SRX4200 Services Gateway Hardware Guide...
Страница 30: ...Copyright 2019 Juniper Networks Inc 30 SRX4200 Services Gateway Hardware Guide...
Страница 64: ...Copyright 2019 Juniper Networks Inc 64 SRX4200 Services Gateway Hardware Guide...
Страница 70: ...Copyright 2019 Juniper Networks Inc 70 SRX4200 Services Gateway Hardware Guide...