Powering Off the SRX5800 Services Gateway
NOTE:
After powering off a power supply, wait at least 60 seconds before turning it back on.
To power off the services gateway:
1. On the external management device connected to the Routing Engine, issue the request system halt
operational mode command. The command shuts down the Routing Engine cleanly, so its state
information is preserved.
user@host>
request system halt
2. Wait until a message appears on the console confirming that the operating system has halted.
For more information about the command, see Junos OS System Basics and Services Command Reference
at
www.juniper.net/documentation/
3. Attach an ESD grounding strap to your bare wrist, and connect the strap to one of the ESD points on
the chassis.
4. Switch off the power supplies:
•
For an AC-powered services gateway, move the AC input switch on the chassis above each AC power
supply to the off (O) position. If the services gateway is equipped with high-capacity AC power
supplies, you must also move the AC input switch on each power supply to the off (O) position.
•
For a DC-powered services gateway, move the DC circuit breaker on each DC power supply faceplate
to the off (O) position.
Performing the Initial Software Configuration for the
SRX5800
IN THIS SECTION
SRX5800 Services Gateway Software Configuration Overview | 250
Initially Configuring the SRX5800 Services Gateway | 250
Performing Initial Software Configuration Using J-Web | 256
249
Содержание SRX 5800
Страница 1: ...SRX5800 Services Gateway Hardware Guide Published 2020 02 10 ...
Страница 23: ......
Страница 30: ...Figure 2 Rear View of a Fully Configured AC Powered Services Gateway Chassis 31 ...
Страница 111: ...LEDs 112 ...
Страница 121: ...Port and Interface Numbering 122 ...
Страница 127: ...Port and Interface Numbering 128 ...
Страница 161: ......
Страница 179: ... One SRX5K MPC IOC2 Modular Port Concentrator with two Modular Interface Cards MICs 180 ...
Страница 180: ... One SRX5K 40GE SFP I O card IOC 181 ...
Страница 205: ......
Страница 261: ......
Страница 324: ...c Upload the configuration to RE2 from the USB device 325 ...
Страница 365: ...Figure 143 Installing an SPC 366 ...
Страница 367: ...368 ...
Страница 422: ...5 CHAPTER Troubleshooting Hardware Troubleshooting the SRX5800 425 ...
Страница 423: ......
Страница 457: ......
Страница 473: ...475 ...
Страница 476: ...Restricted Access Area Warning 478 ...
Страница 483: ...485 ...
Страница 496: ...Jewelry Removal Warning 498 ...
Страница 499: ...Operating Temperature Warning 501 ...
Страница 509: ...DC Power Disconnection Warning 511 ...
Страница 513: ...DC Power Wiring Sequence Warning 515 ...
Страница 516: ...DC Power Wiring Terminations Warning 518 ...
Страница 519: ...DC Power Disconnection Warning 521 ...
Страница 523: ...DC Power Wiring Sequence Warning 525 ...
Страница 526: ...DC Power Wiring Terminations Warning 528 ...