The default primary-role priority value for all devices is 128. You should always configure two spine devices
with the highest primary-role priority to ensure the Routing Engine role is assigned to a spine device.
In a nonprovisioned VCF, you must manually configure every VCP.
Configuration File Management in a VCF
You configure a VCF by logging onto the primary Routing Engine and making configuration changes. See
the next section for information on logging into a VCF.
The configuration file that is modified when you are on the primary Routing Engine is automatically shared
with all other devices in the VCF when it is committed. Each device stores it’s own copy of the configuration
file.
Logging into a Virtual Chassis Fabric
The recommended method of logging into a VCF is through the use of a Virtual Management Ethernet
(VME) interface. The VME interface is a logical interface representing all of the out-of-band management
ports on the member devices. When you connect to the VCF configuration using the VME interface’s IP
address, the connection is always redirected to the management port on device in the primary Routing
Engine role. The VME interface is not tied to a device, so it can always be used to log in to the VCF even
after the primary Routing Engine changes. We recommend cabling the management ports—an me or em
interface—on each Routing Engine in your VCF to support the VME interface.
If you log in to the console port of any member device in a VCF, your session is automatically redirected
to the device acting in the primary Routing Engine role.
Understanding Interface Numbering
Interfaces in Junos OS are specified as follows:
type-fpc/pic/port
A VCF applies this convention as follows:
•
type—The interface type.
•
fpc—Flexible PIC Concentrator. In a VCF, the fpc is the member ID of the switch. For instance, the fpc
of member 16 in the VCF is 16.
•
pic—the number of the PIC (Physical Interface Card) on the member device.
•
port—the port number.
For more detailed information on interface numbering, see Understanding Interface Naming Conventions.
7
Содержание QFX3500
Страница 1: ...Virtual Chassis Fabric Hardware Documentation Published 2020 11 06...
Страница 225: ...Translation The emitted sound pressure is below 70 dB A per EN ISO 7779 201...
Страница 229: ...205...
Страница 238: ...Unterminated Fiber Optic Cable Warning 214...
Страница 246: ...Restricted Access Warning 222...
Страница 249: ...225...
Страница 257: ...Jewelry Removal Warning 233...
Страница 260: ...Operating Temperature Warning 236...
Страница 271: ...DC Power Disconnection Warning 247...
Страница 275: ...DC Power Wiring Sequence Warning 251...
Страница 278: ...DC Power Wiring Terminations Warning 254...
Страница 408: ...Understanding Virtual Chassis Fabric Configuration 4 Understanding Virtual Chassis Fabric Components 384...
Страница 410: ...Figure 130 All QFX5110 VCF g050760 Figure 131 QFX5110 VCF with QFX5100 24Q Leaf Devices 386...
Страница 412: ...Figure 132 QFX5100 24Q as a Leaf Device in a QFX5110 VCF 388...
Страница 565: ...Table 105 System Information continued Description Field Inventory details 541...
Страница 602: ...6 PART Troubleshooting Restoring Junos OS 579 Returning Hardware 586 Alarms and System Log Messages 623...