NOTE:
Each PDM slot not occupied by a AC PDM must be covered by a PDM blank panel.
Installing an MX2000 Router Three-Phase Wye AC Power Distribution Module
Each three-phase wye AC PDM weighs approximately 12 lb (5.44 kg). To install a three-phase wye AC
PDM:
WARNING:
Before performing AC power procedures, ensure that power is removed
from the AC circuit. To ensure that all power is off, locate the circuit breaker on the
panel board that services the AC circuit, switch the circuit breaker to the off position,
and tape the switch handle of the circuit breaker in the off position.
CAUTION:
To maintain proper cooling and prevent thermal shutdown of the operating
power supply unit, each PDM slot must contain either a PDM or a blank panel. If you
remove a PDM, you must install a replacement PDM or a blank panel shortly after the
removal.
NOTE:
After powering off a PDM, wait at least 60 seconds before turning the circuit breaker
back on.
NOTE:
The PDMs are hot swappable in a redundant configuration. However, you cannot convert
to a DC configuration while the system is on.
1. Make sure that the voltage across the AC power source cord is 0 V and that there is no chance that
the cord might become active during the installation process.
2. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to
one of the ESD points on the chassis.
3. [Optional]—If you are switching from a DC PDM to an AC PDM, see Converting an MX2000 Router
Between AC and DC Power for instructions on how to change the setting on the internal bar of the power
distribution unit (PDU) cage to AC.
596
Содержание MX2010
Страница 1: ...MX2010 Universal Routing Platform Hardware Guide Published 2019 12 03...
Страница 28: ......
Страница 30: ...MX2010 Power System Description 95 MX2010 Cooling System Description 45 4...
Страница 54: ...MX2010 Router Overview 3 MX Series Router Interface Names MX2010 Port and Interface Numbering 90 28...
Страница 144: ...MX2010 DC Power 48 V System Electrical Specifications 201 122...
Страница 146: ......
Страница 233: ......
Страница 258: ...Figure 85 Removing an AC Power Distribution Module Before Installing the MX2010 Router D g007439 241...
Страница 259: ...Figure 86 Removing a DC Power Distribution Module 48 V Before Installing the MX2010 Router D g007431 242...
Страница 273: ...Figure 98 Loading the MX2010 Router into the Rack g007436 256...
Страница 294: ...Figure 113 Reinstalling an AC Power Distribution Module g007440 D 277...
Страница 295: ...Figure 114 Reinstalling a DC Power Distribution Module 48 V D g007432 278...
Страница 373: ...4 PART Installing and Replacing Components Installing Components 359 Replacing Components 429...
Страница 374: ......
Страница 620: ......
Страница 715: ...6 PART Troubleshooting Hardware Troubleshooting Components 703...
Страница 716: ......
Страница 744: ......
Страница 767: ...Remove the shipping brackets and hardware and set them aside Guide the router in the shipping crate 754...
Страница 772: ......
Страница 775: ...763...
Страница 783: ...772...
Страница 796: ...Jewelry Removal Warning 787...
Страница 799: ...Operating Temperature Warning 790...
Страница 808: ...DC Power Disconnection Warning 799...
Страница 812: ...DC Power Wiring Sequence Warning 803...
Страница 815: ...DC Power Wiring Terminations Warning 806...