Safety Warnings
WARNING:
See installation instructions before connecting the router to a power
source. This is a summary of safety warnings. For a complete list of warnings for this
router, including translations, see the MX104 Universal Routing Platform Hardware Guide
at
https://www.juniper.net/documentation/
WARNING:
The intrabuilding port(s) of the router is suitable for connection to
intrabuilding or unexposed wiring or cabling only. The intrabuilding port(s) of the router
MUST NOT be metallically connected to interfaces that connect to the OSP or its
wiring. These interfaces are designed for use as intrabuilding interfaces only (Type 2
or Type 4 ports as described in GR-1089-CORE, Issue 6) and require isolation from
the exposed OSP cabling. The addition of primary protectors is not sufficient protection
to connect these interfaces metallically to OSP wiring.
CAUTION:
Before removing or installing components of a router, attach an ESD strap
to an ESD point, and place the other end of the strap around your bare wrist. Failure
to use an ESD strap could result in damage to the router.
CAUTION:
Use an external surge protective device (SPD) at the AC input of the router.
•
Only trained and qualified personnel should install or replace the router.
•
Perform only the procedures described in this Quick Start or the MX104 Universal Routing Platform
Hardware Guide. Other services should be performed by authorized service personnel only.
•
Before installing the router, read the guidelines for site preparation in the MX104 Universal Routing
Platform Hardware Guide to make sure that the site meets power, environmental, and clearance
requirements for the router.
•
When installing the router, do not use a ramp inclined more than 10 degrees.
•
To prevent injury, keep your back straight and lift with your legs, not your back.
•
Mount the router at the bottom of the rack if it is the only unit in the rack.
25
Содержание MX104
Страница 6: ...Figure 2 MX104 Rack Clearance and Chassis Dimensions 6 ...
Страница 8: ...Figure 3 Installing the Front Mounted Router in the Rack 3 1 Mounting screws Rack 2 MX104 router 8 ...
Страница 11: ...Figure 4 Grounding Points on the MX104 Router 2 1 Screws Grounding cable lug 11 ...
Страница 20: ...Figure 11 Connecting a DC Power Cable to an MX104 DC Power Supply 20 ...